Troubleshooting
•
Check the servo drive current consumption.
•
Avoid simultaneous acceleration of all servo drives.
•
Decrease the acceleration value.
9.2.2.6 DC link Overpower (Error 0x2313/0x161)
This fault applies to the PSM 510.
Possible Causes
•
The PSM 510 was operating at over 140% of the nominal power rating for too long.
Troubleshooting
•
Check the current consumption.
9.2.2.7 PT Power Overload (Error 0x2314/0x162)
This fault applies to the PSM 510.
Possible Causes
•
The PSM 510 was operating at 100–140% of the nominal power rating for too long.
Troubleshooting
•
Check the current consumption.
9.2.2.8 UAUX Overcurrent (Error 0x2391/0x125)
This fault applies to the DAM 510.
Possible Causes
•
The servo drives are consuming more power on the U
AUX
line than allowed.
Troubleshooting
•
Check the number of attached servo drives with the shell diagrams in the VLT
®
Servo Drive System ISD 510, DSD 510, MSD 510
Design Guide.
•
Avoid simultaneous lifting of the servo drive brakes.
9.2.2.9 UAUX Overvoltage (Error 0x3292/0x133)
This fault applies to the DAM 510.
Possible Causes
•
Incorrect U
AUX
supply.
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 169
Danfoss A/S © 2019.10