6.16.4.3.7.2 Adding IP Addresses and Subnets
Procedure
1. Open SIMOTION SCOUT
®
.
2. Select the menu [Project
→
Accessible notes].
3. If accessible nodes are found in another subnet, the
Add IP addresses / subnet masks
window is displayed and shows them.
e3
0b
h6
12
.1
0
Illustration 103: Accessible Nodes
4. Click on
Yes
to accept the addresses.
5. The IP address/subnet mask is now added.
NOTICE
-
If more than one Danfoss servo drive is used in the same PROFINET
®
network, each servo drive must have a different
name and IP address.
-
The last number of the IP address is the ID that is used in the VLT
®
Servo Toolbox software to identify the device.
-
When the
Accessible nodes
tab is closed, the addresses are retained. The newly added addresses are only discarded
when SIMOTION SCOUT
®
is closed.
6.16.4.4 Direct Communication
6.16.4.4.1 Overview
For Ethernet-based fieldbus communication (direct communication), the VLT
®
Servo Toolbox must use a dedicated network interface
on the VLT
®
Servo Toolbox host system. Do not use this network interface simultaneously for any other communication.
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 139
Danfoss A/S © 2019.10