8-14 Configurable Control Word CTW
Option:
Function:
Selection of control word bit 10 if it is active low or active high
[0]
None
[1] *
Profile default
[2]
CTW Valid, active low
8-50 Coasting Select
Option:
Function:
Select control of the coasting function via the terminals (digital input) and/or via the bus.
[0]
Digital input
[1]
Bus
Activates Start command via the serial communication port or fieldbus option.
[2]
Logic AND
Activates Start command via the fieldbus/serial communication port, AND additionally via one of the
digital inputs.
[3] *
Logic OR
Activates Start command via the fieldbus/serial communication port OR via one of the digital inputs.
NB!
This parameter is active only when par.8-01
is set to [0]
Digital and control word
.
MCA 121 EtherNet/IP
6 Parameters
MG.90.J2.02 - VLT
®
is a registered Danfoss trademark