130BE309.10
Aux 1
Aux 2
Safe 1
Safe 2
A
2
n
SAB
1
B
PLC
. . .
A
Fieldbus
B
General purpose network
Illustration 6.19 Logical View of Indirect Ethernet-based
Fieldbus Communication (Communication via PLC)
NOTICE
The logical view only shows the connectivity from a
high-level software perspective and does not reflect the
actual physical topology of the network.
Direct communication
For Ethernet-based fieldbus communication (direct
communication), the ISD Toolbox must use a dedicated
network interface on the ISD Toolbox host system. This
network interface should not simultaneously be used for
any other communication.
Aux 1
Aux 2
Safe 1
Safe 2
A
2
n
SAB
1
B
. . .
130BE310.10
A
Fieldbus
B
General purpose network
Illustration 6.20 Logical View of Direct Ethernet-based Fieldbus
Communication
NOTICE
The logical view only shows the connectivity from a
high-level software perspective and does not reflect the
actual physical topology of the network.
6.5.4.1 Network Settings for Indirect
Communication
Any network interface can be used to communicate
through a PLC and a dedicated network interface is not
needed.
When establishing the communication through a PLC, the
ISD Toolbox configures a routing table using the selected
Network Address Translation (NAT)
. Adding a route to the
Windows routing table requires administrator privileges.
Therefore, administrator credentials may be requested
when initializing the connection.
Carry out the following steps to enable indirect communi-
cation.
Disable IPv6 on the network interfaces used for communi-
cation on the PC:
1.
Open the
Network and Sharing Center
.
2.
Select
Change adapter settings
.
3.
Right-click on the network interface used for
fieldbus communication and select
Properties
.
4.
If the
TCP/IPv6
is available for the network
interface, disable it.
Illustration 6.21 Local Area Connection Properties
Commissioning
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.
57
6
6