0-30 Custom Readout Unit
Option:
Function:
[124] CFM
[127] ft3/h
[140] ft/s
[141] ft/min
[160] Degree Fahr
[170] psi
[171] lb/in2
[172] in WG
[173] ft WG
[180] hp
0-31 Custom Readout Min Value
Range:
Function:
0 CustomRea-
doutUnit
*
[ 0 - 999999.99
CustomRea-
doutUnit]
This parameter allows the
choice of the min. value of
the custom defined readout
(occurs at zero speed). It is
only possible to select a value
different to 0 when selecting
a linear unit in
. For quadratic
and cubic units, the minimum
value will be 0.
0-32 Custom Readout Max Value
Range:
Function:
100 CustomRea-
doutUnit
*
[ 0.0 - 999999.99
CustomRea-
doutUnit]
This parameter sets the
max value to be shown
when the speed of the
motor has reached the set
value for
.
0-37 Display Text 1
Range:
Function:
[0 - 0 ] In this parameter it is possible to write an individual
text string to be read via serial communication.
Only used when running BACnet.
0-38 Display Text 2
Range:
Function:
[0 - 0 ] In this parameter it is possible to write an individual
text string to be read via serial communication.
Only used when running BACnet.
0-39 Display Text 3
Range:
Function:
[0 - 0 ] In this parameter it is possible to write an individual
text string to be read via serial communication.
Only used when running BACnet.
3.1.4 0-4* LCP
Enable, disable and password protect individual keys on
the LCP.
0-40 [Hand on] Key on LCP
Option:
Function:
[0] Disabled Select
[0] Disabled
to avoid accidental start of the
adjustable frequency drive in Hand mode.
[1] Enabled [Hand on] key is enabled.
0-42 [Auto on] Key on LCP
Option:
Function:
[0] Disabled Select
[0] Disabled
to avoid accidental start of the
adjustable frequency drive from LCP.
[1] Enabled [Auto on] key is enabled.
0-44 [Off/Reset] Key on LCP
Option:
Function:
[0]
Disabled
[1]
Enabled
[7]
Enable Reset Only
3.1.5 0-5* Copy/Save
Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
Option:
Function:
[0] No copy
[1] All to LCP
Copies all parameters in all set-ups from the
adjustable frequency drive memory to the LCP
memory. For service purposes, it is
recommended to copy all parameters to the
LCP after commissioning.
[2] All from
LCP
Copies all parameters in all set-ups from the
LCP memory to the adjustable frequency drive
memory.
[3] Size indep.
from LCP
Copies only the parameters that are
independent of the motor size. The latter
selection can be used to program several
adjustable frequency drives with the same
function without disturbing motor data that are
already set.
Parameters
VLT
®
HVAC Basic Drive Programming Guide
3-4
MG18B222 - VLT
®
is a registered Danfoss trademark
3
3
Содержание VLT HVAC Drive FC 100 Series
Страница 1: ...MAKING MODERN LIVING POSSIBLE Programming Guide VLT HVAC Basic Drive ...
Страница 2: ......
Страница 14: ...Introduction VLT HVAC Basic Drive Programming Guide 1 8 MG18B222 VLT is a registered Danfoss trademark 1 1 ...
Страница 28: ...How to Program VLT HVAC Basic Drive Programming Guide 2 14 MG18B222 VLT is a registered Danfoss trademark 2 2 ...
Страница 100: ...Troubleshooting VLT HVAC Basic Drive Programming Guide 4 8 MG18B222 VLT is a registered Danfoss trademark 4 4 ...
Страница 116: ...Parameter Lists VLT HVAC Basic Drive Programming Guide 5 16 MG18B222 VLT is a registered Danfoss trademark 5 5 ...
Страница 121: ...Index VLT HVAC Basic Drive Programming Guide MG18B222 VLT is a registered Danfoss trademark 6 5 ...
Страница 122: ...www danfoss com drives MG18B222 130R0221 MG18B222 Rev 2012 10 22 ...