5.3.4 Wall Mounting the Drive
H13 and H14 are chassis drives intended to be mounted on a wall or on a mounting plate within an enclosure. To wall mount the
drive, use the following steps.
Procedure
Fasten 2 M10 bolts in the wall to align with the fastener slots at the bottom of drive.
Slide the lower fastener slots in the drive over the M10 bolts.
Tip the drive against the wall, and secure the top with 2 M10 bolts in the mounting holes.
Example
1
2
e3
0b
g2
88
.1
0
Illustration 43: Drive-to-wall Mounting Holes
1
Top mounting holes
2
Lower fastener slots
AJ363928382091en-000101 / 130R0983
58 | Danfoss A/S © 2021.04
Mechanical Installation
Considerations