Area
Title
Functions
1
Mains input
•
Three-phase AC line power
supply to the adjustable
frequency drive
2
Rectifier
•
The rectifier bridge converts
the AC input to DC current to
supply inverter power
3
DC bus
•
Intermediate DC bus circuit
handles the DC current
4
DC reactors
•
Filter the intermediate DC
circuit voltage
•
Prove line transient protection
•
Reduce RMS current
•
Raise the power factor
reflected back to the line
•
Reduce harmonics on the AC
input
5
Capacitor bank
•
Stores the DC power
•
Provides ride-through
protection for short power
losses
6
Inverter
•
Converts the DC into a
controlled PWM AC waveform
for a controlled variable
output to the motor
7
Output to motor
•
Regulated three-phase output
power to the motor
8
Control circuitry
•
Input power, internal
processing, output, and motor
current are monitored to
provide efficient operation
and control
•
User interface and external
commands are monitored and
performed
•
Status output and control can
be provided
Table 1.2 Legend to
Introduction
VLT
®
Refrigeration Drive Instruction Manual
MG16J122 - VLT
®
is a registered Danfoss trademark
1-3
1
1
Содержание VLT FC 103
Страница 1: ...MAKING MODERN LIVING POSSIBLE Instruction Manual VLT Refrigeration Drive FC 103 75 400 kW ...
Страница 2: ......
Страница 4: ...Safety VLT Refrigeration Drive Instruction Manual MG16J122 VLT is a registered Danfoss trademark ...
Страница 8: ...Contents VLT Refrigeration Drive Instruction Manual MG16J122 VLT is a registered Danfoss trademark ...
Страница 93: ...Index VLT Refrigeration Drive Instruction Manual MG16J122 VLT is a registered Danfoss trademark 12 5 ...
Страница 94: ...www danfoss com drives MG16J122 130R0414 MG16J122 Rev 2013 04 22 ...