Par.
No. #
Parameter description
Default value
4-set-up
Change during
operation
Conversion
index
Type
15-62 Option Ordering No
ExpressionLimit
All set-ups
FALSE
0
VisStr[8]
15-63 Option Serial No
ExpressionLimit
All set-ups
FALSE
0
VisStr[18]
15-70 Option in Slot A
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-71 Slot A Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-9* Parameter Info
15-92 Defined Parameters
0 N/A
1 set-up
TRUE
0
Uint16
15-97 Application Type
0 N/A
1 set-up
TRUE
0
Uint32
15-98 Drive Identification
0 N/A
1 set-up
FALSE
0
VisStr[56]
6.1.14 16-** Data Readouts
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conversion
index
Type
16-0* General Status
16-00 Control Word
0 N/A
1 set-up
TRUE
0
Uint16
16-01 Reference [Unit]
0 ReferenceFeedbackUnit
1 set-up
TRUE
-3
Int32
16-02 Reference [%]
0%
1 set-up
TRUE
-1
Int16
16-03 Status Word
0 N/A
1 set-up
TRUE
0
Uint16
16-05 Main Actual Value [%]
0%
1 set-up
TRUE
-2
Int16
16-09 Custom Readout
0 CustomReadoutUnit
1 set-up
TRUE
-2
Int32
16-1* Motor Status
16-10 Power [kW]
0 kW
1 set-up
TRUE
-3
Uint32
16-11 Power [hp]
0 hp
1 set-up
TRUE
-3
Uint32
16-12 Motor Voltage
0 V
1 set-up
TRUE
-1
Uint32
16-13 Frequency
0 Hz
1 set-up
TRUE
-1
Uint32
16-14 Motor current
0 A
1 set-up
TRUE
-2
Uint16
16-15 Frequency [%]
0%
1 set-up
TRUE
-1
Uint16
16-16 Torque [Nm]
0 Nm
All set-ups
FALSE
-1
Int32
16-18 Motor Thermal
0%
1 set-up
TRUE
0
Uint8
16-22 Torque [%]
0%
All set-ups
FALSE
0
Int16
16-26 Power Filtered [kW]
0 kW
1 set-up
FALSE
0
Int32
16-27 Power Filtered [hp]
0 hp
1 set-up
FALSE
-3
Int32
16-3* Drive Status
16-30 DC Link Voltage
0 V
1 set-up
TRUE
0
Uint32
16-34 Heatsink Temp.
0 °C
1 set-up
TRUE
100
Int8
16-35 Inverter Thermal
0%
1 set-up
TRUE
0
Uint8
16-36 Inv. Nom. Current
0 A
1 set-up
TRUE
-2
Uint16
16-37 Inv. Max. Current
0 A
1 set-up
TRUE
-2
Uint16
16-38 SL Controller State
0 N/A
1 set-up
TRUE
0
Uint8
16-39 Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint16
16-5* Ref. & Feedb.
16-50 External Reference
0%
1 set-up
TRUE
-1
Int16
16-52 Feedback[Unit]
0 ProcessCtrlUnit
1 set-up
TRUE
-3
Int32
16-6* Inputs & Outputs
16-60 Digital Input
0 N/A
1 set-up
TRUE
0
Uint16
16-61 Terminal 53 Setting
[0] Current mode
1 set-up
TRUE
-
Uint8
16-62 Analog Input AI53
1 N/A
1 set-up
TRUE
-2
Uint16
16-63 Terminal 54 Setting
[0] Current mode
1 set-up
TRUE
-
Uint8
16-64 Analog Input AI54
1 N/A
1 set-up
TRUE
-2
Uint16
16-65 Analog Output AO42 [mA]
0 mA
1 set-up
TRUE
-2
Uint16
Parameter Lists
Programming Guide
MG03N202
Danfoss A/S © 11/2015 All rights reserved.
137