6.1.2 0-** Operation/Display
Par.
No. #
Parameter description
Default value
4-set-up
Change during
operation
Conversion
index
Type
0-0* Basic Settings
0-01
Language
[0] English
1 set-up
TRUE
-
Uint8
0-03
Regional Settings
[0] International
1 set-up
FALSE
-
Uint8
0-04
Operating State at Power-up
[0] Resume
All set-ups
TRUE
-
Uint8
0-06
GridType
ExpressionLimit
1 set-up
FALSE
-
Uint8
0-07
Auto DC Braking
[1] On
1 set-up
FALSE
-
Uint8
0-1* Set-up Operations
0-10
Active Set-up
[1] Set-up 1
1 set-up
TRUE
-
Uint8
0-11
Programming Set-up
[9] Active Set-up
1 set-up
TRUE
-
Uint8
0-12
Link Setups
[20] Linked
All set-ups
FALSE
-
Uint8
0-2* LCP Display
0-20
Display Line 1.1 Small
1602
All set-ups
TRUE
-
Uint16
0-21
Display Line 1.2 Small
1614
All set-ups
TRUE
-
Uint16
0-22
Display Line 1.3 Small
1610
All set-ups
TRUE
-
Uint16
0-23
Display Line 2 Large
1613
All set-ups
TRUE
-
Uint16
0-24
Display Line 3 Large
1502
All set-ups
TRUE
-
Uint16
0-3* LCP Custom Readout
0-30
Custom Readout Unit
[1] %
1 set-up
TRUE
-
Uint8
0-31
Custom Readout Min Value
0 CustomReadoutUnit
1 set-up
TRUE
-2
Int32
0-32
Custom Readout Max Value
100 CustomReadoutUnit
1 set-up
TRUE
-2
Int32
0-37
Display Text 1
0 N/A
1 set-up
TRUE
0
VisStr[20]
0-38
Display Text 2
0 N/A
1 set-up
TRUE
0
VisStr[25]
0-39
Display Text 3
0 N/A
1 set-up
TRUE
0
VisStr[25]
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
[1] Enabled
All set-ups
TRUE
-
Uint8
0-42
[Auto on] Key on LCP
[1] Enabled
All set-ups
TRUE
-
Uint8
0-44
[Off/Reset] Key on LCP
[1] Enabled
All set-ups
TRUE
-
Uint8
0-5* Copy/Save
0-50
LCP Copy
[0] No copy
1 set-up
FALSE
-
Uint8
0-51
Set-up Copy
[0] No copy
1 set-up
FALSE
-
Uint8
0-6* Password
0-60
Main Menu Password
0 N/A
1 set-up
TRUE
0
Uint16
6.1.3 1-** Load and Motor
Par.
No. #
Parameter description
Default value
4-set-up
Change during
operation
Conversion
index
Type
1-0* General Settings
1-00
Configuration Mode
[0] Open Loop
All set-ups
TRUE
-
Uint8
1-01
Motor Control Principle
[1] VVC+
All set-ups
FALSE
-
Uint8
1-03
Torque Characteristics
[1] Variable Torque
All set-ups
FALSE
-
Uint8
1-06
Clockwise Direction
[0] Normal
1 set-up
FALSE
-
Uint8
1-08
Motor Control Bandwidth
ExpressionLimit
All set-ups
FALSE
-
Uint8
1-1* Motor Selection
1-10
Motor Construction
[0] Asynchron
All set-ups
FALSE
-
Uint8
1-11
Motor Selection
[0] Default Motor Selection
All set-ups
FALSE
-
uint8
1-12
Motor ID
[Default Motor]
All set-ups
FALSE
0
VisStr[16]
1-14
Damping Gain
120%
All set-ups
TRUE
0
Int16
1-15
Low Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-16
High Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16