2 Product Overview
2.1 Introduction
The product overview applies to both FCP 106 and FCM
106.
VLT
®
DriveMotor FCP 106
The delivery comprises the frequency converter only. A
wall mount adapter plate, or motor adapter plate and
power crimp terminals are also required for installation.
Order the wall mount kit or adapter plate and power crimp
terminals separately.
195NA447.10
Illustration 2.1 FCP 106
VLT
®
DriveMotor FCM 106
The frequency converter is mounted onto the motor at
delivery. The combined FCP 106 and motor is known as
the VLT
®
DriveMotor FCM 106.
195NA419.10
Illustration 2.2 FCM 106
2.1.1 Gasket
Mounting of the FCP 106 onto a motor requires fitting a
customised gasket. The gasket fits between the motor
adapter plate and the motor.
No gasket is supplied with the FCP 106 frequency
converter.
Therefore, before installation, design and test a gasket to
fulfil the ingress protection requirement (for example IP55,
IP66, or Type 4X).
Requirements for gasket:
•
Maintain the ground connection between
frequency converter and motor. The frequency
converter is grounded to the motor adapter plate.
Use a wire connection between the motor and
the frequency converter.
•
Use a UL-approved material for the gasket, when
UL listing or recognition is required for the
assembled product.
Product Overview
VLT
®
DriveMotor FCP 106/FCM 106
10
Danfoss A/S © 06/2016 All rights reserved.
MG03M202