Decentral Solutions
Programming, FCD
300
■
Operation & Display
001 Language
(LANGUAGE)
Value:
✭
English (ENGLISH)
[0]
German (DEUTSCH)
[1]
French (FRANCAIS)
[2]
Danish (DANSK)
[3]
Spanish (ESPANOL)
[4]
Italian (ITALIANO)
[5]
Function:
This parameter is used to choose the language
to be shown in the display whenever the LCP
control unit is connected.
Description of choice:
There is a choice of the languages shown. The
factory setting may vary.
002 Local/remote operation
(OPERATION SITE)
Value:
✭
Remote operation (REMOTE)
[0]
Local operation (LOCAL)
[1]
Function:
There is a choice of two different modes of operation
of the variable frequency drive.
Remote operation
[0]
or
Local operation
[1]. See also parameter 013
Local
control
if
Local operation
[1] is selected.
Description of choice:
If
Remote operation
[0] is selected, the variable
frequency drive is controlled via:
1. the control terminals or via serial communication.
2. the [START] key. This cannot, however, override
stop commands transmitted via the digital inputs
or via serial communication.
3. the [STOP/RESET] and [JOG] keys, on the
condition that these are active.
If
Local operation
[1], is selected, the variable
frequency drive is controlled via:
1. the [START] key. This cannot, however, override
stop commands via the digital inputs (see
parameter 013
Local control
).
2. the [STOP/RESET] and [JOG] keys, on the
condition that these are active.
3. the [FWD/REV] key, on the condition that is has
been selected as active in parameter 016
Local
reversing
, and that parameter 013
Local control
is set at
Local control and open loop
[1] or
Local
control as parameter 100
[3]. Parameter 200
Output frequency range
is set at
Both directions
.
4. parameter 003
Local reference
where the reference
can be set using the [+] and [-] keys.
5. an external control command that can be
connected to the digital inputs (see parameter
013
Local control
).
NOTE
The [JOG] and [FWD/REV] keys are located
on the LCP control unit.
003 Local reference
(LOCAL REFERENCE)
Value:
Par.013
Local control
must be set to [1] or [2]:
0 - f
MAX
(par. 202)
✭
000,000.000
Par. 013
Local control
must be set to [3] or [4] and
parameter 203
Reference/feedback range
to [0]:
Ref
MIN
- Ref
MAX
(par. 204-205)
✭
000,000.000
Par. 013
Local control
must be set to [3] or [4] and
parameter 203
Reference/feedback range
to [1]:
- Ref
MAX
- + Ref
MAX
(par. 204-205)
✭
000,000.000
Function:
In this parameter, the local reference can be set
manually. The unit of the local reference depends on the
configuration selected in parameter 100
Configuration
.
Description of choice:
In order to protect the local reference, parameter
002
Local/remote operation
must be set to
Local operation
[1]. Local reference cannot be
set via serial communication.
■
Setup configuration
There is a choice of four Setups (parameter Setups),
which can be programmed independently of one
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.90.F2.22 - VLT is a registered Danfoss trademark
99