
37-11 Pos. Brake Wear Limit
Range:
Function:
0
*
[0 - 1073741824 ]
37-12 Pos. PID Anti Windup
Option:
Function:
[0]
Disable
[1]
*
Enable
37-13 Pos. PID Output Clamp
Range:
Function:
1000
*
[1 - 10000 ]
37-14 Pos. Ctrl. Source
Option:
Function:
[0]
*
DI
[1]
FieldBus
37-15 Pos. Direction Block
Option:
Function:
[0]
*
No Blocking
[1]
Block Reverse
[2]
Block Forward
37-17 Pos. Ctrl Fault Behaviour
Option:
Function:
[0]
*
Ramp Down&Brake
[1]
Brake Directly
37-18 Pos. Ctrl Fault Reason
Option:
Function:
[0]
*
No Fault
[1]
Homing Needed
[2]
Pos. HW Limit
[3]
Neg. HW Limit
[4]
Pos. SW Limit
[5]
Neg. SW Limit
[7]
Brake Wear Limit
[8]
Quick Stop
[9]
PID Error Too Big
[12]
Rev. Operation
[13]
Fwd. Operation
[20]
Can not find home position
37-19 Pos. New Index
Range:
Function:
0
*
[0 - 255 ]
4.7.3 32-** Motion Control Basic Settings
32-11 User Unit Denominator
Range:
Function:
1
*
[1 - 65535 ]
32-12 User Unit Numerator
Range:
Function:
1
*
[1 - 65535 ]
32-67 Max. Tolerated Position Error
Range:
Function:
2000000
*
[1 - 2147483648 ]
32-80 Maximum Allowed Velocity
Range:
Function:
1500 RPM
*
[1 - 30000 RPM]
32-81 Motion Ctrl Quick Stop Ramp
Range:
Function:
1000 ms
*
[50 - 3600000 ms]
4.7.4 33-** Motion Control Adv. Settings
33-00 Homing Mode
Select the homing mode.
Option:
Function:
[0]
*
Not forced
[1]
Forced manual homing
[2]
Forced automated homing
33-01 Home Offset
Range:
Function:
0
*
[-1073741824 - 1073741824 ]
33-02 Home Ramp Time
Range:
Function:
10 ms
*
[1 - 1000 ms]
33-03 Homing Velocity
Range:
Function:
100 RPM
*
[-1500 - 1500 RPM]
33-04 Homing Behaviour
Option:
Function:
Define the behaviour when the home
switch is found: Reversing without index
(0 pulse) search, or forwarding without
index search.
[1]
*
Reverse no index
[3]
Forward no index
33-41 Negative Software Limit
Range:
Function:
-500000
*
[-1073741824 - 1073741824 ]
33-42 Positive Software Limit
Range:
Function:
500000
*
[-1073741824 - 1073741824 ]
Positioning Control
Application Guide
MG06E102
Danfoss A/S © 11/2014 All rights reserved.
25
4
4