5.2 Parameter Lists and Options, Software Version 8.10 (Standard)
5.2.1 0-** Operation / Display
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
0-0* Basic Settings
0-01 Language
[0] English
1 set-up
TRUE
-
Uint8
0-02 Motor Speed Unit
ExpressionLimit
2 set-ups
FALSE
-
Uint8
0-03 Regional Settings
ExpressionLimit
2 set-ups
FALSE
-
Uint8
0-04 Operating State at Power-up (Hand)
[1] Forced stop, ref=old
All set-ups
TRUE
-
Uint8
0-09 Performance Monitor
0 %
All set-ups
TRUE
-1
Uint16
0-1* Set-up Operations
0-10 Active Set-up
[1] Set-up 1
1 set-up
TRUE
-
Uint8
0-11 Edit Set-up
[1] Set-up 1
All set-ups
TRUE
-
Uint8
0-12 This Set-up Linked to
[0] Not linked
All set-ups
FALSE
-
Uint8
0-13 Readout: Linked Set-ups
0 N/A
All set-ups
FALSE
0
Uint16
0-14 Readout: Edit Set-ups / Channel
0 N/A
All set-ups
TRUE
0
Int32
0-15 Readout: actual setup
0 N/A
All set-ups
FALSE
0
Uint8
0-2* LCP Display
0-20 Display Line 1.1 Small
ExpressionLimit
All set-ups
TRUE
-
Uint16
0-21 Display Line 1.2 Small
1614
All set-ups
TRUE
-
Uint16
0-22 Display Line 1.3 Small
1610
All set-ups
TRUE
-
Uint16
0-23 Display Line 2 Large
1613
All set-ups
TRUE
-
Uint16
0-24 Display Line 3 Large
1602
All set-ups
TRUE
-
Uint16
0-25 My Personal Menu
ExpressionLimit
1 set-up
TRUE
0
Uint16
0-3* LCP Custom Readout
0-30 Unit for User-defined Readout
[0] None
All set-ups
TRUE
-
Uint8
0-31 Min Value of User-defined Readout
0 CustomReadoutUnit
All set-ups
TRUE
-2
Int32
0-32 Max Value of User-defined Readout
100 CustomReadoutUnit
All set-ups
TRUE
-2
Int32
0-33 Source for User-defined Readout
[240] Default Source
All set-ups
TRUE
-
Uint8
0-37 Display Text 1
0 N/A
1 set-up
TRUE
0
VisStr[
25]
0-38 Display Text 2
0 N/A
1 set-up
TRUE
0
VisStr[
25]
0-39 Display Text 3
0 N/A
1 set-up
TRUE
0
VisStr[
25]
0-4* LCP Keypad
0-40 [Hand on] Key on LCP
ExpressionLimit
All set-ups
TRUE
-
Uint8
0-41 [Off] Key on LCP
ExpressionLimit
All set-ups
TRUE
-
Uint8
0-42 [Auto on] Key on LCP
ExpressionLimit
All set-ups
TRUE
-
Uint8
0-43 [Reset] Key on LCP
ExpressionLimit
All set-ups
TRUE
-
Uint8
0-44 [Off/Reset] Key on LCP
[1] Enabled
All set-ups
TRUE
-
Uint8
0-45 [Drive Bypass] Key on LCP
[1] Enabled
All set-ups
TRUE
-
Uint8
0-5* Copy/Save
0-50 LCP Copy
[0] No copy
All set-ups
FALSE
-
Uint8
0-51 Set-up Copy
[0] No copy
All set-ups
FALSE
-
Uint8
0-6* Password
0-60 Main Menu Password
100 N/A
1 set-up
TRUE
0
Int16
0-61 Access to Main Menu w/o Password
[0] Full access
1 set-up
TRUE
-
Uint8
0-65 Personal Menu Password
200 N/A
1 set-up
TRUE
0
Int16
0-66 Access to Personal Menu w/o Password
[0] Full access
1 set-up
TRUE
-
Uint8
0-67 Bus Password Access
0 N/A
All set-ups
TRUE
0
Uint16
0-68 Safety Parameters Password
300 N/A
1 set-up
TRUE
0
Uint16
0-69 Password Protection of Safety Parameters
[0] Disabled
1 set-up
TRUE
-
Uint8