Number Description
Warning Alarm/trip Alarm/trip
lock
Parameter reference
211
Position limit
X
X
–
Parameter 3-06 Minimum Position
,
pa-
rameter 3-07 Maximum Position
,
parame-
ter 4-73 Position Limit Function
212
Homing not done
–
X
–
Parameter 17-80 Homing Function
213
Homing timeout
–
X
–
Parameter 17-85 Homing Timeout
214
No sensor input
–
X
–
–
215
Start fwd/rev
X
X
–
Parameter 4-74 Start Fwd/Rev Function
216
Touch timeout
–
X
–
Parameter 4-75 Touch Timeout
220
Configuration File Version not sup-
ported
X
–
–
–
246
Power card supply
–
–
X
–
250
New spare part
–
–
X
–
251
New type code
–
X
X
–
280
Emcy m service warning
X
–
–
–
281
Emcy OPR unexpected
X
–
–
–
430
PWM disabled
–
X
–
–
1
Cannot be auto reset via
parameter 14-20 Reset Mode
.
(X) Dependent on parameter.
A trip is the action following an alarm. The trip coasts the motor and is reset by pressing [Reset] or by a digital input (
parameter
group 5-1* Digital Inputs
). The original event that caused an alarm cannot damage the drive or cause dangerous conditions.
A trip lock is an action when an alarm occurs, which could damage the drive or connected parts. A trip lock situation can only be
reset by cycling power.
7.1.3 Indicator Light
Table 1435: Indicator Light
Warning
Yellow
Alarm
Flashing red
Trip locked
Yellow and red
7.1.4 Alarm Word, Warning Word, and Extended Status Word
Table 1436: Description of Alarm Word
Bit Hex
Dec
Alarm word
Alarm word 2
Alarm word 3
Parameter 16-90 Alarm Word Parameter 16-91 Alarm Word 2
Parameter 16-97 Alarm
Word 3
Alarm Word Extended Status Word
0
00000001 1
Brake check (A28)
Servicetrip, read/ write
Temp. input error
1
00000002 2
Pwr.card temp (A69)
Servicetrip, (reserved)
Memory module fault
AU275636650261en-000101 / 130R0334 | 695