Option Name
Description
Selects the absolute position mode instead of the relative position mode.
[126]
Activate touch
N O T I C E
This option is available only with software version 48.20 and newer.
Activates the touch probe positioning mode.
[127]
Deactivate touch
N O T I C E
This option is available only with software version 48.20 and newer.
Deactivates the touch probe positioning mode.
[128]
Target inverse
N O T I C E
This option is available only with software version 48.20 and newer.
Changes the sign of the active target position value.
[129]
Target
N O T I C E
This option is available only with software version 48.20 and newer.
The active target position is not changed.
[130]
Act. speed mode
N O T I C E
This option is available only with software version 48.20 and newer.
Activates the speed mode when option
[9] Positioning
or option
[10] Synchronization
is selected
in
parameter 1-00 Configuration Mode
.
[131]
Deact. speed mode
N O T I C E
This option is available only with software version 48.20 and newer.
Deactivates the speed mode and activates the option selected in
parameter 1-00 Configuration
Mode
.
5.13.6 13-9* User-defined Alerts and Readouts
Parameters in this group allow the configuration of application-specific triggers for triggering the drive to perform a certain action,
show the status on the LCP, and represent it accordingly in
parameter 13-97 Alert Alarm Word
,
parameter 13-98 Alert Warning Word
,
and
parameter 13-99 Alert Status Word
. In
parameter 13-91 Alert Action
, it is possible to select drive functionalities such as
info only
,
stop
,
running to max
, and
force drive to trip
.
Use the following parameters to configure the drive to show a message and perform an action when a specific event occurs:
Parameter 13-90 Alert Trigger
– the event that triggers the user-defined action and message.
Parameter 13-91 Alert Action
– the action that the drive performs when the event defined in
parameter 13-90 Alert Trigger
occurs.
Parameter 13-92 Alert Text
– the text that the drive shows in the display when the event defined in
parameter 13-90 Alert Trigger
occurs.