Set current as percentage of rated motor current,
parameter 1-24 Motor Current
. Is used when enabled in
parameter 1-70 Start Mode
.
Parameter 2-07 Parking Time
Table 157: Parameter 2-07 Parking Time
2-07 Parking Time
Default value: 3 s
Parameter type: Range, 0.1 - 60 s
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
Set the duration of the parking current set in
parameter 2-06 Parking Current
, once activated.
5.3.2 2-1* Brake Energy Funct.
Parameter group for selecting dynamic brake parameters. Only valid for drives with brake chopper.
Parameter 2-10 Brake Function
Table 158: Parameter 2-10 Brake Function
2-10 Brake Function
Default value: [1] Resistor brake
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
Op-
tion
Name
Description
[0]
Off
No brake resistor installed.
[1]*
Resistor
brake
A brake resistor is incorporated in the system for dissipation of surplus brake energy as heat. Connecting a
brake resistor allows a higher DC-link voltage during braking (generating operation). The resistor brake
function is only active in drives with an integral dynamic brake.
[2]
AC brake
Improves braking without using a brake resistor. This parameter controls an overmagnetization of the mo-
tor when running with a generatoric load. This function can improve the OVC function. Increasing the elec-
trical losses in the motor allows the OVC function to increase the braking torque without exceeding the
overvoltage limit.
N O T I C E
The AC brake is not as efficient as dynamic braking with resistor. AC brake is for VVC+ mode in both open
and closed loop.
Parameter 2-11 Brake Resistor (ohm)
Table 159: Parameter 2-11 Brake Resistor (ohm)
2-11 Brake Resistor (ohm)
Default value: Size related
Parameter type: Range, 0 - 65535 Ohm
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Set the brake resistor value in Ω. This value is used for monitoring the power to the brake resistor in
parameter 2-13 Brake Power
Monitoring
. This parameter is only active in drives with an integral dynamic brake. Use this parameter for values without decimals.
For a selection with 2 decimals, use
parameter 30-81 Brake Resistor (ohm)
.
AU275636650261en-000101 / 130R0334
114 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide