37-13 Pos. PID Output Clamp
This parameter clamps the total output of the PID. A setting of
1000 corresponds to 100% of
parameter 32-80 Maximum Allowed
.
Range:
Function:
1000
*
[1 - 10000 ]
37-14 Pos. Ctrl. Source
Selects the control source for positioning control.
Option:
Function:
[0]
*
DI
[1]
FieldBus
37-15 Pos. Direction Block
Use this parameter to configure whether to block a direction,
and the direction to be blocked.
Option:
Function:
[0]
*
No Blocking
[1]
Block Reverse
[2]
Block Forward
37-16 Pos. Power Recovery
Configures whether to enable the power recovery function.
Option:
Function:
[0]
Disable
[1]
*
Enable
37-17 Pos. Ctrl Fault Behaviour
This parameter determines the behaviour of the frequency
converter after a fault is detected.
Option:
Function:
[0]
*
Ramp Down&Brake
[1]
Brake Directly
37-18 Pos. Ctrl Fault Reason
READ-ONLY PARAMETER: The current fault reason of the alarm
POSITION CTRL FAULT
is displayed in this parameter.
Option:
Function:
[0]
*
No Fault
[1]
Homing Needed
[2]
Pos. HW Limit
[3]
Neg. HW Limit
[4]
Pos. SW Limit
[5]
Neg. SW Limit
[7]
Brake Wear Limit
[8]
Quick Stop
[9]
PID Error Too Big
[12]
Rev. Operation
[13]
Fwd. Operation
[20]
Can not find home position
37-19 Pos. New Index
The currently latched index number.
Range:
Function:
0
*
[0 - 255 ]
4.24.3 37-2* Center Winder
37-20 Winder Mode Selection
Use the machine for either winding or unwinding.
Option:
Function:
[0]
*
Wind
[1]
Unwind
37-21 Tension Set Point
Set the desired running tension.
Range:
Function:
0 %
*
[0 - 100 %]
37-22 Taper Set Point
Use this parameter to change the tension setpoint while the
diameter increases.
Range:
Function:
0 %
*
[-110 - 110 %]
37-23 Partial Roll Diameter Value
Use this parameter to preset the diameter when a partial roll is
loaded on the winder. For unwinding applications, use this
parameter to set the full roll diameter.
Range:
Function:
5 %
*
[5 - 100 %]
37-24 Core1 Diameter
Set the main core value to be used on the winder. This
parameter must be set for the smallest core diameter for both
winding and unwinding applications.
Range:
Function:
5 %
*
[5 - 100 %]
37-25 Core2 Diameter
Set a secondary core diameter for winding applications, or a
secondary full roll diameter for unwinding applications.
Range:
Function:
5 %
*
[5 - 100 %]
37-26 Winder Jog Speed
Set the winder jog speed percentage. This percentage value is
used for both forward and reverse jogging speed.
Range:
Function:
0 %
*
[0 - 100 %]
37-27 TLD Low Limit
Set the low limit for the tension limit detection.
Range:
Function:
0 %
*
[0 - 100 %]
Parameter Descriptions
Programming Guide
MG06C602