
VLT
®
8000 AQUA
Introduction
■
Definitions
Definitions are given in alphabetical order.
AEO:
Automatic Energy Optimization - function that
dynamically adjusts the current supplied to a
variable torque load to optimize motor power
factor and motor efficiency.
analog inputs:
The analog inputs can be used for controlling various
functions of the frequency converter.
There are two types of analog inputs:
Current input, 0-20 mA
Voltage input, 0-10 V DC.
analog ref.
A signal transmitted to input 53, 54 or 60.
Can be voltage or current.
analog outputs:
There are two analog outputs, which are able to supply
a signal of 0-20 mA, 4-20 mA or a digital signal.
Automatic motor adjustment, AMA:
Automatic motor adjustment algorithm, which
determines the electrical parameters for the
connected motor, at standstill.
AWG:
AWG means American Wire Gauge, i.e. the American
measuring unit for cable cross-section.
Control command:
By means of the control unit and the digital inputs, it is
possible to start and stop the connected motor.
Functions are divided into two groups, with
the following priorities:
Group 1
Reset, Coasting stop, Reset and
Coasting stop, DC braking, Stop and the
[OFF/ STOP] key.
Group 2
Start, Pulse start, Reversing, Start
reversing, Jog and Freeze output
Group 1 functions are called Start-disable commands.
The difference between group 1 and group 2 is that
in group 1 all stop signals must be cancelled for the
motor to start. The motor can then be started by
means of a single start signal in group 2.
A stop command given as a group 1 command
results in the display indication STOP.
A missing stop command given as a group 2 command
results in the display indication STAND BY.
CT:
Constant torque: used for e.g. heavy, solid
sludge pumps and centrifuges.
Digital inputs:
The digital inputs can be used for controlling various
functions of the frequency converter.
Digital outputs:
There are four digital outputs, two of which activate
a relay switch. The outputs are able to supply
a 24 V DC (max. 40 mA) signal.
f
JOG
The output frequency from the frequency converter
transmitted to the motor when the jog function is
activated (via digital terminals or serial communication).
f
M
The output frequency from the frequency converter
transmitted to the motor.
f
M,N
The rated motor frequency (nameplate data).
f
MAX
Maximum output frequency transmitted to the motor.
f
MIN
Minimum output frequency transmitted to the motor.
I
M
The current transmitted to the motor.
I
M,N
The rated motor current (nameplate data).
Initializing:
If initializing is carried out (see parameter 620
Operating mode
), the frequency converter
returns to the factory setting.
I
VLT,MAX
The maximum output current.
I
VLT,N
The rated output current supplied by the
frequency converter.
LCP:
The control panel, which makes up a complete
interface for control and programming of VLT 8000
AQUA. The control panel is detachable and may,
as an alternative, be installed up to 3 metres away
MG.83.A2.02 - VLT is a registered Danfoss trademark
5
Содержание VLT 8000 AQUA series
Страница 29: ...VLT 8000 AQUA Introduction TYPE CODE Table Ordering form MG 83 A2 02 VLT is a registered Danfoss trademark 29 ...
Страница 52: ...VLT 8000 AQUA Mechanical dimensions MG 83 A2 02 VLT is a registered Danfoss trademark 52 ...
Страница 60: ...VLT 8000 AQUA All enclosure types VLT 8152 8652 380 480 V MG 83 A2 02 VLT is a registered Danfoss trademark 60 ...
Страница 63: ...VLT 8000 AQUA Installation MG 83 A2 02 VLT is a registered Danfoss trademark 63 ...