VLT® 5000 Crane
Appendix
■
Read parameter description elements
With
Read Parameter Description Elements
it is possible
to read the characteristics of a parameter which could
be eg.
Name, Default value, conversion
, etc.
The table below shows the available parameter
description elements:
Index
Description
1
Basic characteristics
2
No of elements (array types)
4
Unit of measure
6
Name
7
Lower limit
8
Upper limit
20
Default value
21
Additional characteristics
In the following example
Read Parameter Description
Elements
is chosen on parameter 001,
Language
, and
the requested element is index 1
Basic characteristics
.
Basis characteristics (index 1):
The Basic characteristics command is split up
in two parts representing basic behaviour and
datatype. The Basic characteristics return a 16
bit value to the master in PWE
LOW
.
The basic behaviour indicates whether eg. text is
available or the parameter is an array as single bit
information in the high byte of PWE
LOW
.
The datatype part indicates if a parameter is signed
16, unsigned 32 in the low byte of PWE
LOW
.
PWE high basic behaviour:
Bit
Description
15
Active parameter
14
Array
13
Parameter value can only be reset
12
Parameter value different from factory setting
11
Text available
10
Additional text available
9
Read only
8
Upper and lower limit not relevant
0-7
Data type
Active parameter
is only active when communicating
through Profibus.
Array
means that the parameter is an array.
If bit 13 is true, the parameter can only be
reset, not written to.
If bit 12 is true, the parameter value is different
from the factory setting.
Bit 11 indicates that text is available.
Bit 10 indicates that additional text is available. Eg.
parameter 001,
Language
, contains text for index field
0,
English
, and for index field 1,
German
.
If bit 9 is true, the parameter value is read-only
and cannot be changed.
If bit 8 is true, upper and lower limits of the
parameter value are not relevant.
PWE
LOW
datatype
Dec.
Datatype
3
Signed 16
4
Signed 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Visible string
10
Byte string
13
Time difference
33
Reserved
35
Bit sequence
Example
In this example, the master reads the Basic
characteristics of parameter 001,
Language
.
The following telegram must be sent to the
frequency converter:
STX
LGE
ADR
PKE
IND
PWE
HIGH
PWE
LOW
PCD1
PCD2
BCC
02
0E
01
40 01
00 01
00 00
00 00
XX XX
XX XX
XX
MG.50.N4.02 - VLT is a registered Danfoss trademark
105