Страница 1: ...Danfoss Heating TPOne RF Electronic Programmable Room Thermostat Installation Guide...

Страница 2: ...an intelligent programmable heating control made easy TPOne includes features which are designed to save energy Look out for the leaf symbol throughout this guide for settings which can directly influ...

Страница 3: ...trol accuracy and enhances system efficiency 2 ErP 4 Product Class Specifications TPOne RF RX1 S Operating Voltage 2 5 3VDC 2x AA batteries 230Vac 50 60Hz Output relay Volt Free Setting temperature ra...

Страница 4: ...ing Thermostat or Remote Room Sensor positioning Please note This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the local...

Страница 5: ...r Wiring Window switch contact RX1 S Receiver ELECTRONICS N L N L 2 3 4 COM ON OFF 230Vac 1 RX1 S Receiver NOTE Remote Sensor to be wired with 1mm 2 core double insulated cable only Cable length shoul...

Страница 6: ...ed and TPOne will recall the settings you have defined The TPOne Standby Mode allows you to switch your heating off when not required although the thermostat continues to monitor the room temperature...

Страница 7: ...The required temperature for Away mode is selectable in the Temperature setting see User Menu Temperatures Asleep Asleep Mode selects the nightime comfort temperature which is set between the end of...

Страница 8: ...OK will be shown on the display when it can be used or is required Menu Back Press O to exit a menu option Pressing O while in a setting will result in that setting change not be accepted O will also...

Страница 9: ...urce This is indicated by the Heat Calling icon The TPOne RF is connected by radio signal to a receiver The Radio Frequency icon will be displayed to confirm that this connection is active and that th...

Страница 10: ...Once set the further changes can be made in the user and installer setting menus OK RF Pairing RF Pairing Language English OK Set Date 04 02 2016 OK Set Time 24hr 10 45 OK OK OK OK OK OK OK OK OK READ...

Страница 11: ...mperatures AM 21 0 o OK 21 5 o 10 45 Thurs User Menu Temperatures OK OK OK OK OK OK OK OK 21 0 o Follow this routine to set required Comfort Mode temperatures Changes can be made for each mode once al...

Страница 12: ...hurs OK OK OK OK OK OK Follow this routine to set Heating Schedule Days can be set individually or grouped and options for weekdays and weekend settings can be selected All day combinations can then h...

Страница 13: ...hedule Heating User Menu Mon Tues Weds Thurs Fri Sat Sun OK OK OK OK From To 06 00 08 30 OK OK OK Home Period 2 OK From To 12 30 13 30 OK OK OK Home Period 3 OK From To 17 30 22 30 OK OK OK OK OK Sele...

Страница 14: ...ull user set heating schedule to a manually set temperature only thermostat In schedule mode the thermostat will follow the user set heating schedule In manual mode the user set schedule will be ignor...

Страница 15: ...p temperature will be set during the night between the home periods Default settings Home AM 20 C Home PM 20 C Away 15 C Asleep 15 C Holiday Holiday feature allows you to set in advance your holiday d...

Страница 16: ...ssed on the TPOne the display backlight will come on to aid viewing Where backlight is not required this feature can be switched off Switching the backlight off will increase battery life Default sett...

Страница 17: ...ng is turned up or down at the programmed times Delayed start or Economy Setting Set the period start times in the normal way taking into account the time that the building takes to heat on an average...

Страница 18: ...5 C Temperature Override This establishes the degree of manual temperature override available to the user No Limit Limited 2 C or No Override Default No Limit Daylight Saving Choose to set automatic...

Страница 19: ...mit setting the output will be turned off until the temperature has dropped by 2 C A warning will be shown on the display that the floor limit temperature has been exceeded Room temperature will be co...

Страница 20: ...eating Once set the service interval timer can only be reset or deactivated by an installer having the correct access code Additional information on Service Interval can be found later in this guide N...

Страница 21: ...cancelled the alarm will recommence the following day at noon If the boiler is not serviced before the due date an audible warning will start each day at noon the service icon will also be displayed...

Страница 22: ...22 TPOne RF Default tables SCHEDULE DEFAULTS 06 30 22 30 Weekend 07 30 22 30 06 30 08 30 Weekend 07 30 09 30 16 30 22 30 06 30 08 30 Weekend 07 30 09 30 11 30 13 30 16 30 22 30 1 2 3...

Страница 23: ...Danfoss Heating 23 AM 20 C PM 20 C 15 C 15 C TEMPERTURE DEFAULTS Default tables Continued...

Страница 24: ...displayed where a window open switch has been fitted and the window is opened see page 19 Product Lock This will be displayed where a product lock switch has been fitted and the switch has been activa...

Страница 25: ...other large appliances or mirrors in line of sight between the transmitter and receiver as these will prevent communication between the TPOne RF and receiver Pairing Failed When first installed the s...

Страница 26: ...ll continue to control heating but the reason for the overheat may still exist The floor heating system should be checked to ensure overheating does not reoccur Sensor Fail If the TPOne in built tempe...