Parameter lists
A.2 Output
74
SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
Parameter
Default value Value range
Access
level
Description
9
Flowrate unit
m
3
/h
(Page 83)
R/W
Flow unit as text for actual flowrate.
Change the unit in parameter table if the
device menu "Unit guide (offline)" does not
list the wanted unit.
Note: The device display can show "m
3
/s"
unit only - other units cannot be shown on
the display, but will be used and shown
online via PDM.
10
Maximum flow
Qmax
R/W
Maximum flow
373
Low flow cut-off
0.25
0 ... 10
R/W
If the flow comes below this percentage of
Qmax, then the flow value is set to zero
20
Vendor name
Danfoss A/S
Read
Danfoss A/S, Denmark
21
Module type
11
0 ... 14
Read
Type of flowmeter
22
Software version
2.03
Software version of the flowmeter
23
Product code number
Product de-
pendent
Production sales code number (the first
part of the system number on the name-
plate)
24
System Serial number Product de-
pendent
R/W
Production number (the second part of the
system number on the nameplate
25
Transmitter serial num-
ber
Product de-
pendent
HW key Serial number of the electronics
26
Sensor serial number
Product de-
pendent
Serial number of the sensor
373
Low flow cut-off
0.25
0 ... 10
R/W
If the flow comes below this percentage of
Qmax, then the flow value is set to zero
A.2
Output
Table A- 2
Output parameters
Parameter
Default
value
Value range
Access
level
Description
100 Actual date and time
Product
dependent
R/W
Actual date and time (day-month-year
and hours:minutes:seconds)
101 Totalizer 1
0
-2000000001 ...
+2000000001
Read
Volume for totalization register 1
102 Totalizer 2
0
-2000000001 ...
+2000000001
Read
Volume for totalization register 2
103 Customer totalizer 3
0
Read
Customer totalizer 3 based on totalizer 1
set up
104 Reset customer totalizer 3
No
No, Yes
R/W
Reset of customer totalizer
105 Customer totalizer 3 reset
date
last reset
date
dd-mm-yyyy,
hh:mm:ss
Date and time when customer totalizer
has been reset
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...