5. Check magnet carrier for cracks , deformations, wearing, and for contamination with magnetic
particles
W
Warning
A thorough inspection with the angle sensor removed is a strong indicator of pump and hydraulic
system contamination and filtration quality.
Reassembly
1. Using new magnet carrier screws with locking compound (K115) install the magnet carrier (K105) to
pump swashplate through the housing. Torque the screws to 4.5 Nm [3.3 lbf-ft].
W
Warning
Used magnet carrier screws may loosen and lead to premature failure. Ensure that new screws with
locking compound are utilized.
2. Install the locating dowels (K185) into the dowel holes.
3. Lubricate new O-ring (K175) with petroleum jelly. Install the O-ring to the angle sensor housing
(K265) first.
4. Install angle sensor housing (K265) with O-ring (K175) to housing with 4 screws (K195) and torque to
5.9 Nm [4.4 lbf-ft].
Service Manual
Series 45 E Frame Open Circuit Pumps
Minor repair
38 |
©
Danfoss | September 2016
AX00000024en-US0401
Содержание Series 45
Страница 1: ...Service Manual Open Circuit Axial Piston Pumps Series 45 E Frame powersolutions danfoss com...
Страница 41: ...Service Manual Series 45 E Frame Open Circuit Pumps Danfoss September 2016 AX00000024en US0401 41...
Страница 42: ...Service Manual Series 45 E Frame Open Circuit Pumps 42 Danfoss September 2016 AX00000024en US0401...
Страница 43: ...Service Manual Series 45 E Frame Open Circuit Pumps Danfoss September 2016 AX00000024en US0401 43...