T-category with ambient temperature at 65°C [149°F]
Oil inlet temperature
T-category
≤ 79°C [174°F]
T5
79 - 90°C [174 - 194°F]
T4
Description of the EX code h version
Ex marking (EN 80079-36 standard part)
Description
EU Marking
Protection principle
h
Explosion protection marking
Equipment group
I / II
Equipment protection level (EPL)
Mb / Gb
T-class
T5...T4
Ex marking (EU Directive part)
Description
EU Marking
CE conformity marking
CE
Explosion protection marking
Equipment Group
I / II
Equipment Category
M2 / 2G
EPL/Equipment category
EPL/Equipment category
Definition
Level of protection Typical zone of
application
IEC
EU
EPL
Group
Category
Group
Mines
Very high
N/A
Ma
I
M1
I
High
Mb
M2
Gas atmosphere
Very high
0
Ga
II
1G
II
High
1
Gb
2G
Enhanced
2
Gc
3G
Technical Information
PVG-EX 32 Proportional Valve Group
PVG-EX Introduction
©
Danfoss | June 2019
BC290860493426en-000103 | 7
Содержание PVG-EX 32
Страница 1: ...Technical Information Proportional Valve Group PVG EX 32 www danfoss com ...
Страница 138: ...Technical Information PVG EX 32 Proportional Valve Group 138 Danfoss June 2019 BC290860493426en 000103 ...
Страница 139: ...Technical Information PVG EX 32 Proportional Valve Group Danfoss June 2019 BC290860493426en 000103 139 ...
Страница 140: ...Technical Information PVG EX 32 Proportional Valve Group 140 Danfoss June 2019 BC290860493426en 000103 ...