![Danfoss PVG 16 PVAS Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/danfoss/pvg-16-pvas/pvg-16-pvas_technical-information_507221046.webp)
Compensated PVB with LS A/B
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independency on the load pressure of other functions used
simultaneously. The integrated LS
A/B
relief valve is used to limit the maximum work port build-up on the
A/B-ports individually.
The compensated PVB with LS
A/B
features:
•
Integrated LS shuttle network
•
Integrated compensator
Compensated PVB with LS A/B schematic
1
0
2
A
Pp
T0
LX
P
T
B
Technical specification for A/B-port
Max. continuous pressure
Max. intermittent pressure
Max. rated flow
350 bar [5076 psi]
420 bar [6090 psi]
60 l/min [15 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG 16 Proportional Valve Group
PVB Basic Modules
46 |
©
Danfoss | December 2018
BC00000211en-000901