© Danfoss | August 2018
AQ00000211 |
83
ENGINEERING TOMORROW
Steering wheel programs
When the PVED-CLS is in Off-road steering mode, one of the 5 different programs can be chosen which can be set with
some individual parameters for the steering ratio, and some parameters which are common for all 5 programs such as soft-
stop, anti-jerk etc. Furthermore, if the an OSPE/EHi-E system is being used and the OSP steering unit is specified as an
LSRM-type (see OSPE Steering valve, Technical information), then either Off-road reaction or Off-road non-reaction can
be chosen.
10.1
BLOCK DIAGRAM
Fast steer and EFU
Anti jerk
Soft-stop
Control / no-control
decision
Flow to spool
position conversion
SVC
Backlash/filter
Figure 40
10.2
BACKLASH
If the neutral springs in the OSP affect the SASAIID sensor readings when the driver releases the steering wheel and
hereby unintentionally operates the valve, a backlash region (P3570) can be applied to prevent it. The size of the backlash
region is normally set equal to the angle related to response. However, any set-value greater than zero leads to slower
steering responds. Therefore, to minimize these effects, the steering wheel, sensor shaft and underlying mechanics must
be designed as stiff as possible.
Since this parameter only affects changes in the set-point, stability problems in closed loop are not related to the set-value
of this parameter.
The value recommended by Danfoss, which is 0.5 Deg., i.e. P3570 set to 5, does not remove elasticity effects.
Important
Setting this value higher than the recommended value, could lead to slow steering response
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Backlash region
P3570
U8
dDeg
Backlash limit to use in the backlash filter in the steering wheel control
algorithm
Resolution: 1dDeg = 0.1Deg
OEM
0
200
5
Table 35
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...