17.4.5
Analog Sensor Calibration Data
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Primary analogue sensor
max left position
P3205
U16
mVolts
Primary analogue sensor voltage output for leftmost position
OEM, Dealer
0
6000
500
Primary analogue sensor
max right position
P3207
U16
mVolts
Primary analogue sensor voltage output for rightmost position
OEM, Dealer
0
6000
4500
Primary analogue sensor
neutral position
P3209
U16
mVolts
Primary analogue sensor voltage output for neutral position
OEM, Dealer
0
6000
2500
Redundant analogue sensor
max left position
P3211
U16
mVolts
Redundant analogue sensor voltage output for leftmost position
OEM, Dealer
0
6000
500
Redundant analogue sensor
max right position
P3213
U16
mVolts
Redundant analogue sensor voltage output for rightmost position
OEM, Dealer
0
6000
4500
Redundant analogue sensor
neutral position
P3215
U16
mVolts
Redundant analogue sensor voltage output for neutral position
OEM, Dealer
0
6000
2500
5V sensor supply for
primary analogue sensor
during calibration
P3217
U16
mVolts
Measured Supply voltage during calibration of the primary analogue sensor
OEM, Dealer
4650
5350
5000
5V sensor supply for
redundant analogue sensor
during calibration
P3219
U16
mVolts
Measured Supply voltage during calibration of the redundant analogue
sensor
OEM, Dealer
4650
5350
5000
Automatically adjusted
cylinder stroke volume
(analogue WAS)
P3221
U16
ccm
Automatically adjusted cylinder stroke volume, for using analogue WAS,
found during WAS auto-calibration
OEM, Dealer
100
65535
65535
Automatically adjusted
maximum steer angle to
left side (analogue WAS)
P3223
U16
Deg
Automatically adjusted maximum steer angle to left side, for using
analogue WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Automatically adjusted
maximum steer angle to
right side (analogue WAS)
P3225
U16
Deg
Automatically adjusted maximum steer angle to right side, for using
analogue WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Table 68
Important
For analog sensor calibration data sector, the following rules apply:
P3205 < P3207 < P3209 OR P3205 > P3207 > P3209
AND if P3245 is set to 255 (redundant WAS is present)
P3211 < P3213 < P3215 OR P3211 > P3213 > P3215
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...