132 | © Danfoss | August 2018
AQ00000211
ENGINEERING TOMORROW
Safe on-road mode
Controlling an OSPE, EHPS or EHi valve with a PVED-CLS is designed for off-road use only. When the vehicle is
taken from an off-road situation to an on-road situation, a common risk mitigation method is to power off the PVED-
CLS.
If powering off the PVED-CLS is not feasible, Danfoss has implemented an option to use the PVED-CLS to broadcast
wheel angle position on the CAN bus. This functionality will do a soft shut down of the PVED-CLS, to fulfill that the
PVED-CLS is active for broadcasting signals on the CAN bus, when driving on road, but no controlling of the EH is
available (hence SVB and Cut-off valve are off).
For more details on how to setup this architecture and the PVED-CLS, please see the Danfoss document, PVED-CLS
Safety Manual.
PVED
-CLS
DT
06
-12
S
AD2
AD3
Sensor GND
CAN H Safety
CAN L Safety
CutOff out
Battery (-)
Battery (+)
CAN L Main
CAN H Main
5V sensor supply
AD1
1
2
3
4
5
6
7
8
9
10
11
12
Battery
(-)
Battery
(+)
Road switch in
ON-ROAD position
Solenoid Valve
Bridge
EH valve
SW1 signal
validation
SW2 signal
validation
Safe road
switch position
Compari
son
Fault
(enter safe
state)
Software
Fault
(enter safe
state)
Fault
(enter safe state)
Redundant data
Primary data
Road switch
SW1
SW2
11
12 14
22 24
21
Supply
Gnd
COM
NO
Supply
Gnd
COM
NO
Cut
-o
ff coil
DT
06
-2
S
Pin1
Pin2
+
-
Valve
/
COV
K1
K2
Figure 70
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...