![Danfoss PVE 4 Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/danfoss/pve-4-series/pve-4-series_technical-information_4063565044.webp)
•
Ground pins are internally connected.
•
U
DC2
only supplies electronics for feedback signal and error pin on PVEA-DI / PVEH-DI. Two separate
power sources can be used.
AMP version: PVEA–DI/PVEH–DI
Deutsch version: PVEA–DI/PVEH–DI
Black connector
Grey connector
DI-B
DI-A
PVEA-DI/PVEH-DI
1
2
4
3
Pin no.
LED
U
DC1
S
U
Error
U
DC2
P301 105
2
1
Error
3
4
U
S
U
DC
U
DC2
DI-B
DI-A
2
1
3
4
PVEA-DI/PVEH-DI
LED
Standard PVE with SP
Connection PVE with Spool Position (SP)
Connector
U
S
Error
SP
Gnd
U
DC
Deutsch
p 1
p 2
p 4
p 5
p 6
Deutsch version: PVES–SP
Not
connected
Error
Us
3
2
1
4
5
6
Spool position
PVES-SP
U
DC
LED
Standard PVE with NP
Connection PVE with Neutral Power off (NP)
Connector
U
S
Error
Sfb
Gnd
UDC
Deutsch
p 1
p 2
p 4
p 5
p 6
Control (US) for standard mounted PVEA–DI/ PVEH–DI, PVES-SP, PVEA-NP, PVEH-NP
Function
U
S
PWM
Neutral
0,5 • U
DC
50%
Q: P
→
A
0,5
→
0,25 • UDC
50%
→
25%
Q: P
→
B
0,5
→
0,75 • UDC
50%
→
75%
Technical Information
PVE, Series 4 for PVG 32/100/120 and PVHC
Technical Data
44
520L0553 • Rev GD • Jan 2014
Содержание PVE 4 Series
Страница 53: ...Technical Information PVE Series 4 for PVG 32 100 120 and PVHC 520L0553 Rev GD Jan 2014 53...
Страница 54: ...Technical Information PVE Series 4 for PVG 32 100 120 and PVHC 54 520L0553 Rev GD Jan 2014...
Страница 55: ...Technical Information PVE Series 4 for PVG 32 100 120 and PVHC 520L0553 Rev GD Jan 2014 55...