background image

Installation and maintenance 

condensing unit manual

OP-HJZM / HNXM / HRXM / LNYM / LRYM / LJHM

Manual

http://cc.danfoss.com

Содержание OP-HJZM

Страница 1: ...Installation and maintenance condensing unit manual OP HJZM HNXM HRXM LNYM LRYM LJHM Manual http cc danfoss com...

Страница 2: ...e of the condensing unit must be carried out by qualified personnel only Follow these instructions and best practices on refrigeration engineering during installation commissioning maintenance and ser...

Страница 3: ...t or pallet jack for handling Use appropriate and safe lifting equipment Store and transport the unit in an upright position Store the unit between 30 F and 120 F Don t expose the packaging to rain or...

Страница 4: ...erial Use clean and dehydrated system components The suction piping connected to the compressor must be flexible in 3 dimensions to dampen vibrations Furthermore piping has to be done in such a way th...

Страница 5: ...applied to this product it causes transformation of characteristics or the destruction Operation will become unstable when using other than sine waves for the power supply In this case proper control...

Страница 6: ...Such as snow or freezing Check if a line to line short circuit is detected at a connection point of the fan motor It is recommended to protect the circuit with a thermal relay or circuit protector No...

Страница 7: ...intenance Switch off the system and isolate the main power supply Ensure that power supply cannot be switched on during installation All electrical components must be selected as per local standards a...

Страница 8: ...rify that all electrical connections are properly fastened and in compliance with local regulations When a crankcase heater is required it must be energized at least 12 hours before initial start up a...

Страница 9: ...ctions are still adequately fastened Keep the unit clean and verify the absence of rust and oxidation on the unit components tubes and electrical connections The condenser must be checked at least onc...

Страница 10: ...47 4 16 5 7 8 1 2 HRXM0500 2 28 8 49 4 31 5 7 8 1 2 HRXM0600 2 28 8 49 4 31 5 7 8 1 2 HRXM0700 2 28 8 49 4 31 5 7 8 1 2 HRXM0750 2 39 1 61 2 31 5 1 1 8 5 8 HRXM1000 2 39 1 61 2 31 5 1 1 8 5 8 Unit Di...

Страница 11: ...1 8 X 7 8 W D H 2X Knockout 7 8 Liquid Line C L C L Suction Line 2X Double Knockout 1 1 8 X 7 8 W H D 2X Knockout 7 8 C L Suction Line Liquid Line C L 2X Double Knockout 1 1 8 X 7 8 W D H 2X Knockout...

Страница 12: ...BC251686497767en US0801 Electrical wiring diagrams Wiring Diagram 119 8312 Wiring Diagram 119 8313 Electrical Code N HJZM0150 HNXM0200 0400 HRXM0500 LJHM0150 0200 Electrical Code Q HNXM0200 0400 HRXM...

Страница 13: ...51686497767en US0801 Electrical wiring diagrams X 4 2 1 N 3 N O LOAD N C LOAD Wiring Diagram 119 8315 Wiring Diagram 119 8493 Electrical Code Q HJZM0150 LJHM0150 0200 Electrical Code Q LNYM0400 0500 L...

Страница 14: ...Manual 14 BC251686497767en US0801 Electrical wiring diagrams Wiring Diagram 119 8640 Wiring Diagram 119 8641 Electrical Code R HRZM0600 1000 Electrical Code R LRYM0600 0800...

Страница 15: ...op the refrigerant flow through the evaporator 10 Suction pressure decreases and the compressor contactor opens when the pressure drops below the cut out setting on the low pressure control The compre...

Страница 16: ...ensions Length Height in mm in mm HJXM0150 0200 LJHM0150 0300 26 660 19 480 HJXM0200 0300 29 740 22 550 LNYM0400 0500 HJXM0350 0400 31 780 27 700 HRXM0500 0700 LRYM0600 0800 46 1170 28 720 HRXM0750 10...

Страница 17: ......

Страница 18: ...erter Scrolls Danfoss Turbocor Compressors Danfoss Scrolls Danfoss Optyma Condensing Units Danfoss Maneurop Reciprocating Compressors BC251686497767en US0801 Danfoss DCS CC 2019 11 Our products can be...

Отзывы: