Possible error
Information and action
WMS not functioning
Power supply is not connected.
Check power cable and connections.
Power supply has failed.
Check power supply.
Internal software is not functioning.
Only in case of internal malfunction. Switch off and on.
Measured values are clearly incorrect
WMS is not ready for operation.
Check start-up procedure.
Contact skilled personnel or service.
Corrosion on piping, suspension etc.
Corrosion appears
Possible cause: Unsuitable materials.
Remedy: Check project planning.
Table 22: Further WMS troubleshooting
5.5.1.
Reset alarms
When receiving an alarm from the WMS system an action must be taken. The alarms in the WMS-system will not stop the
WMS system from running,
When the cause has be corrected go to the Menu 1. Event Log through the LCP display and select 1-4* Reset Alarm. The
Active Alarm will be showing, press OK to reset it.
Illustration 89: Reset Alarm display
If the alarm does activate again, the alarm has been handled. If the alarm is triggered once again, the right corrections
has still not been made. If correcting alarms as described in Table 21 still has not worked, please contact the supplier of
the WMS.
Reset Alarm
1-4*
[A1]
SP1 Low Flow
Press OK to reset
Alarm