5 Installation/Fitting
5.1 Transport and Delivery
5.1.1 Scope of Delivery
The scope of delivery of the ISD Encoder Box comprises:
•
The encoder box
•
1 SD card, pre-formatted with software installed
•
1 set of plug connectors (see chapter
)
•
These operating instructions
5.1.2 Transport
The maximum weight of a packaged encoder box is
approximately 2.5 kg.
•
Avoid vibration during transportation.
•
Avoid heavy impacts and blows.
5.1.3 Inspection on Receipt
After receiving the delivery, immediately check whether
the scope of delivery matches the shipping documents.
Danfoss will not honour claims for faults registered at a
later time.
Register a complaint immediately:
•
with the carrier in case of visible transport
damage;
•
with the responsible Danfoss representative in
case of visible defects or incomplete delivery.
5.2 Safety Measures during Installation
Always observe the safety instructions in chapter
during installation.
Pay particular attention to ensuring that the following
points are observed carefully:
•
Installation may only be performed by qualified
staff.
•
Installation must be performed with due care and
attention.
•
All safety regulations and protective measures are
complied with, and the environmental conditions
are observed.
•
The documentation is read and understood.
5.3 Installation Environment
Environmental Conditions
The installation must provide the following environmental
conditions to allow the encoder box to be operated safely
and efficiently.
•
The allowable operating ambient temperature
range is not exceeded.
•
The relative humidity is ≤ 85%, non-condensing.
•
The vibration level is ≤ 1 g / 20 m/s
2
without
resonance excitation.
•
Unrestricted ventilation is available.
•
The maximum operating temperature is 40 °C. A
control cabinet climate control should be used if
necessary.
Contact Danfoss if it is not possible to comply with these
environmental conditions.
5.4 Preparation for Installation
Mount the DIN rail on the back wall of the control cabinet.
Installation/Fitting
VLT
®
ISD Encoder Box Operating Instructions
MG75F102 - VLT
®
is a registered Danfoss trademark
17
5
5
Содержание ISD Encoder Box
Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT ISD Encoder Box...
Страница 2: ......
Страница 44: ...www danfoss com drives MG75F102 175R1123 MG75F102 Rev 2012 08 13...