Non Feedback Proportional Electric Control (NFPE) with MOR, options: A8 (12 V) / B8 (24V)
Control manual override "C2"
Depressing the plunger mechanically
moves the control spool. Actuation
allows full stroke pump response as
per coil and rotation dependent
control logic
Control manual override "C1"
Depressing the plunger mechanically
moves the control spool. Actuation
allows full stroke pump response as
per coil and rotation dependent
control logic
Mounting flange
Shaft
2x 64.2 ±0.8
206 ±2.5
Shaft
Control solenoid
connector "C1"
Deutsch DT04-2P
paint free
Control solenoid
connector "C1"
Deutsch DT04-2P
paint free
Case gauge port "M14"
Port ISO 1926-1 - 7/16-20
∅
21 max clearance dia for fitting
Z
CL
CL
Mounting flange
P700 33 400
147.3 ±1.2
120.1 ±1.2
173 ±2.5
58
-45
1
2
P301 320
W (2:1)
Control solenoid Connector “C1” & “C2”
Pin
Assignment
OR
Pin
Assignment
1
Supply
1
Ground
2
Ground
2
Supply
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Controls
©
Danfoss | May 2017