Customer ports
Configuration
Size
080
Axial and radial
1)
DN25 typ 1
L1, L2
2)
M22x1,5
Bleed port
3)
M14x1,5
1)
Split flange Boss per ISO6162, 40 MPa series
2)
Metric O-ring boss
3)
Countersink may be deeper that specified in the standard.
H1F Operating Parameters
Output Speed
Output Speed
Displacement
Unit
Size
080
Rated
Maximum 32°
min
-1
(rpm)
4500
Maximum
Maximum 32°
5000
System and Case Pressure, Ambient Temperature
Parameter
All sizes
System pressure
Maximum working delta
450 bar [6527 psi]
Maximum working abs
480 bar [6962 psi]
Max delta
480 bar [6962 psi]
Max abs
510 bar [7397 psi]
Min low loop
7.5 bar [109 psi]
Case pressure
Rated
3 bar [44 psi]
Maximum
5 bar [73 psi]
Minimum
0.3 bar [4 psi]
Ambient temperature
1)
Maximum
70 °C [158 °F]
Minimum
-40 °C [-40 °F]
1)
Air temperature close to the unit.
H1F Required inlet pressure table (for cylinder block filling)
80cc
Speed (RPM)
Pressure (Bar)
900
2
1400
5
2100
10
2800
15
3200
20
4000
30
This pressure ensures that the cylinder block will be properly filled and that there is no pulling between
piston and shaft.
The required pressure is 0 bar at 0 rpm and increases with rpm.
Service Manual
H1F Bent Axis Fixed Displacement Motors, Size 080
Technical specifications
©
Danfoss | December 2023
AX465363259664en-000102 | 11