5-33 Term X30/7 Digi Out (MCB 101)
Option:
Function:
[16]
Below speed, low
[17]
Above speed, high
[18]
Out of feedb. range
[19]
Below feedback, low
[20]
Above feedback, high
[21]
Thermal warning
[22]
Ready,no thermal W
[23]
Remote,ready,no TW
[24]
Ready, voltage OK
[25]
Reverse
[26]
Bus OK
[27]
Torque limit stop
[28]
Brake: No Brake War
[29]
Brake ready, no fault
[30]
Brake fault (IGBT)
[31]
Relay 123
[32]
Mech brake ctrl
[33]
Safe stop active
[39]
Tracking error
[40]
Out of ref range
[41]
Below reference, low
[42]
Above ref, high
[43]
Extended PID Limit
[45]
Bus ctrl.
[46]
Bus ctrl, 1 if timeout
[47]
Bus ctrl, 0 if timeout
[51]
MCO controlled
[60]
Comparator 0
[61]
Comparator 1
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic rule 0
[71]
Logic rule 1
[72]
Logic rule 2
[73]
Logic rule 3
[74]
Logic rule 4
[75]
Logic rule 5
[80]
SL digital output A
[81]
SL digital output B
[82]
SL digital output C
[83]
SL digital output D
[84]
SL digital output E
[85]
SL digital output F
[120] Local ref active
[121] Remote ref active
[122] No alarm
[123] Start command activ
[124] Running reverse
5-33 Term X30/7 Digi Out (MCB 101)
Option:
Function:
[125] Drive in hand mode
[126] Drive in auto mode
[189] External Fan Control
3.7.4 5-4* Relays
Parameters for configuring the timing and the output
functions for the relays.
5-40 Function Relay
Array [9]
(Relay 1 [0], Relay 2 [1], Relay 3 [2] (MCB 113), Relay 4 [3] (MCB 113),
Relay 5 [4] (MCB 113), Relay 6 [5] (MCB 113), Relay 7 [6] (MCB 105),
Relay 8 [7] (MCB 105), Relay 9 [8] (MCB 105))
Option:
Function:
[0]
*
No operation
All digital and relay outputs are
default set to “No Operation”.
[1]
Control ready
The control card is ready. For
example, Feedback from a drive
where the control is supplied by an
external 24 V (MCB 107) and the main
power to drive is not detected.
[2]
Drive ready
Drive is ready to operate. Line power
and control supplies are OK.
[3]
Drive rdy/rem ctrl
The adjustable frequency drive is
ready for operation and is in auto on
mode.
[4]
Enable / no warning Ready for operation. No start or stop
commands have been applied (start/
disable). No warnings are active.
[5]
Running
Motor is running, and shaft torque
present.
[6]
Running / no
warning
Output speed is higher than the
speed set in
1-81 Min Speed for
Function at Stop [RPM]
Min Speed for
Function at Stop [RPM]. The motor is
running and no warnings.
[7]
Run in range/no
warn
Motor is running within the
programmed current and speed
ranges set in
and
. No
warnings.
[8]
Run on ref/no warn
Motor runs at reference speed. No
warnings.
[9]
Alarm
An alarm activates the output. No
warnings
[10]
Alarm or warning
An alarm or a warning activates the
output.
Parameter Descriptions
FC 300 Programming Guide
MG.33.MA.22 - VLT
®
is a registered Danfoss trademark
3-57
3
3