Intermediate dies are positioned and removed in the same manner
when needed.
After forming heavy fittings, the locking pin (2) may be a little slug-
gish. In this case, use a rubber mallet to loosen the locking pin (2)
by carefully knocking on the die key.
5.4.2 Changing the crimping dies with the quick die change system (only profile
239)
1.
Select the change position for crimping dies in the control by ac-
tivating the button [QDC].
2.
Press the
button to open the crimping tool so that the dies
type PB239 can just be inserted.
3.
Push the eight pins of the quick die change system (1) into the
front holes of the crimping dies (2).
4.
Rotate anti-clockwise and remove the crimping dies (2) from the
deposit.
5.
Check the retaining bolts (3) of the crimping dies for damage.