The amount of inverters depends on the electric machine and converter current ratings. See also the
relevant wiring diagrams.
For an electric machine with option DUAL (two connection boxes each containing one three-phase
system), the electrical connection principles from the inverters are shown in the Figure below.
Connection diagram for DUAL option
For an electric machine with option QUAD (four galvanically isolated three-phase systems), the electrical
connection principles from the inverters are shown in the Figure below.
Connection diagram for QUAD option
Cable gland assembly and power line connection
If you are not using the recommended cable lugs, select cable lugs that leave 10 mm gap
between each and every cable lug on the same connection plate.
The pictures are schematic, and the actual components can look different.