Mechanical mounting connections of the electric machine (horizontal mounting)
1 Shaft of the machine; cylindrical shaft with diameter of 70 mm h7 and contact length of 130 mm.
2 D-end flange (SAE 1/2 transmission housing) and bolt bores (12 pieces) for mounting the electric machine from
the flange.
3 Electric machine lifting eyes.
4 Cooling system connections (bores).
5 Mounting foot stand including the bolt bores (4 pieces) for mounting the electric machine from the foot stand.
6 Foot mounting bolts. (4 pcs of DIN912 M16 socket head). Not included in the delivery.
7 Mounting bolts (12 pcs of DIN912 M12 socket head). Not included in the delivery.
Cooling connections
Make sure that cooling liquid runs freely into and out from the electric machine.
To prevent damage to the cooling connectors, refer to the documentation of the
manufacturer for the correct tightening torque of the cooling liquid nipples.
When selecting cooling liquid nipples, choose nipples that can resist galvanic corrosion.