Max Value:
1
Units:
Boolean
Description: True
The High Voltage DC bus voltage is less than the minimum for which the Danfoss Power
Solutions system is configured.
False
The High Voltage DC bus voltage is greater than the minimum for which the Danfoss
Power Solutions system is configured.
In this condition, the MCU severely limits the torque the system can produce.
7.3.3.24
MCU Under Voltage Warning History
dbc ref:
TCUStat3_MCUUnderVoltageWarningHistory
lsb:
41
msb:
41
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Under Voltage Warning
has been set to True at some point since the last time
MCU power was cycled.
False
MCU
Under Voltage Warning
has not been set to True at any point since the last time
MCU power was cycled.
7.3.3.25
MCU Over Phase Advance
dbc ref:
TCUStat3_MCUOverPhaseAdvance
lsb:
40
msb:
40
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The motor requires excessive phase advance to produce the desired torque.
False
The motor is able to produce the desired torque without requiring excessive phase
advance.
Note: When this condition occurs, the MCU will reduce the maximum torque the system will
produce to that which it can produce without requiring excessive phase advance.