5.3 Tank temperature
Parameters indicated with an ID no. like "1x607" mean a universal
parameter.
x stands for circuit / parameter group.
MENU > Settings > Tank temperature
Charge difference
1x193
Set the number of degrees above the desired DHW temperature that will
result in the DHW heating (charging) temperature.
See Appendix “Parameter ID overview”
Value:
Number of degrees to be added to the desired DHW
temperature to obtain the DHW heating (charging)
temperature.
X
=
Time
# 1 # =
Charging difference (ID 1x193)
# 2 # =
Desired DHW temperature
# 3 # =
Start difference (ID 1x195)
# 4 # =
Actual DHW temperature
# 5# =
DHW heating / charging activity
The desired DHW temperature is related to the tank temperature
sensor.
If two tank temperature sensors are installed, the relation is to the
upper tank temperature sensor.
VI.GU.L2.02
© Danfoss | 2017.09 | 109
Operating Guide ECL Comfort 210/296/310, application A275/A375