Low voltage connections
The durability of the X1-connector is limited to 10 installations / removals by the connector manufacturer.
When powering OFF the electric device, use the POWER_ON input. The power supply (VIN_N and/or VIN_P) can be
disconnected, if desired, after time t
min
has elapsed from the deactivation of POWER_ON (see Figure Disconnecting the
power supply in this chapter). A safe value for t
min
is 5 seconds.
See the correct signal connections and product speci c pin-layout from product data sheets,
Control signals (option dependent)
Basic device supports following CAN-protocols:
CANopen
SAE J-1939
CAN-protocols are alternatives and the choice should be made when placing an order.
The control signals of the electric device are operated via X1-connector.
Low voltage control signal connection includes these functions:
Power supply of the control system of the electric device.
Power On/Off.
Communication channels (CAN).
Digital In/Out.
Analog In.
Emergency stop (according to automotive standards).
External temperature monitoring PT100 and PT1000.
To make sure of correct operation of the control signal, use compatible connector interface
(male/female) and appropriate shielded wiring.
Table 15. Control signal connector information.
Description
Part number
Supplier example
X1-Control signal connector (in the chassis)
Tyco Electronics/AMPSEAL, 35-pin (male)
1-776163-1
http://www.te.com/usa-en/product-1-776163-1.html
X1-Cable connector (mating connector)
Tyco Electronics/AMPSEAL, 35-pin (female)
Case:776164-1
http://www.te.com/usa-en/product-776164-1.html
Pins: 770854-3 (wire 0.5-1.25mm
2
)
http://www.te.com/usa-en/product-770854-3.html
EC-C1200-450
5. Installation
| BC265735231757en-000109
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019 | 51