![Danfoss EC-C1200-450 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/danfoss/ec-c1200-450/ec-c1200-450_user-manual_3449260050.webp)
Table 8. Recommendations for control signal cables
Cable
Cable type and properties
Resolver cabling
shielded cable (twisted pair)
CAN cabling
shielded cable (twisted pair)
SYNC signals (for parallel or dual motor connection)
shielded cable (twisted pair)
Other signals
multistrand wire (0.5-1.5 mm
2
)
High voltage connections
The high voltage connections have a common ground connector.
U
HV
≥ U
LV
The electric device must be installed and connected according to the instructions.
Make sure that all the connected applications are connected to the electric device according to
the product speci c operating voltage.
The electric device is delivered with the power terminal cover mounted. To access the power
connections, remove the mechanical safety feature and the connection box lid.
Table 9. DC connection speci cations (+MC, +AFE, +UG options)
DC-connection
DC link voltage range
0-850 VDC
DC link nominal voltage
750 VDC
Table 10. AC connection speci cations (+MC, +AFE, +UG -options)
AC connection
AC output voltage
0-560 V
EFF
(U
DC
= 800V
DC
)
Output frequency
0...580 Hz. Up to 1000 Hz as option.
Switching frequency
8 kHz
Maximum power
300 kVA
EC-C1200-450
5. Installation
| BC265735231757en-000109
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019 | 49