Figure 16. X1-connector
Cooling connections
Make sure that cooling liquid runs freely in and out from the electric device.
Connect the electric device directly to the cooling circuit.
Make sure that the coolant ow is equal or higher than rated and the coolant temperature at
the inlet of the electric device is lower or equal to the rated temperature.
For more information, see Chapter
and product data sheets. Rated
values can be found on the rating plate of the electric device.
Coolant connections: 2 x 20mm.
Coolant connection in EC-LTS unit 2 x 1/2" bores.
It is recommended to x the hose on the coolant connection with a hose clamp or a hose clip
after the protection cap has been removed.
Use water/glycol mix or pure water with corrosion inhibitor as the coolant.
It is possible for the electric device to monitor and control the temperatures of the Danfoss
PMI family electric machines. Connect the temperature signal to the temperature monitoring pin
of the electric machine and activate the temperature protection feature.