086U8255 Rev 4

UK-specific appendix to  

Installation instructions

DHP-A

DHP-A Opti

DHP-AQ Maxi

DHP-H

DHP-H Opti

DHP-H Opti Pro

DHP-L

DHP-L Opti

DHP-L Opti Pro

Содержание DHP-A

Страница 1: ...VIBMB402 086U8255 Rev 4 UK specific appendix to Installation instructions DHP A DHP A Opti DHP AQ Maxi DHP H DHP H Opti DHP H Opti Pro DHP L DHP L Opti DHP L Opti Pro...

Страница 2: ...gulations 3 1 1 Test results 3 2 About documents and labels 4 2 1 Manufacturer labels 4 3 Piping installation 8 3 1 General 8 3 2 System solution 9 3 3 Discharge pipe arrangement 13 4 Commissioning 14...

Страница 3: ...The water heater is protected with a sacrificial aluminium anode Under normal circumstances no mainte nance is needed E E Note Leave the following documents with the end user This manual Installation...

Страница 4: ...efrigerant Kg 1 2 Connection Electric connection V 400 3N 50Hz Power input Total kW 5 0 8 0 11 0 Power input Heat pump kW 2 0 Power input Auxiliary Heater kW 3 6 9 Pressure Vessel Volume Sec Prim l 18...

Страница 5: ...er input Total kW 3 1 6 1 9 1 Power input Heat pump kW Power input Auxiliary Heater kW 3 6 9 Pressure Vessel Volume Sec Prim l 180 7 5 Design Pressure Sec Prim MPa 1 0 0 3 Test Pressure Sec Prim MPa 1...

Страница 6: ...r 90 95 C Maximum primary working pressure 1 5 bar Immersion heater D76 9 kW 230 V WARNING TO THE USER a Do not remove or adjust any component part of this unvented water heater Contact the installer...

Страница 7: ...valve 6 bar Expansion vessel charge pressure 3 bar Operating pressure 5 5 bar Temp and pressure release valve 10 bar 90 95 C Maximum primary working pressure 1 5 bar Immersion heater D76 9 kW 230 V W...

Страница 8: ...19 liter FITT0052 1 Expansion vessel bracket 132 FITT0053 1 Flexible hose FITT0001 1 Tundish 15x22 mm 129 FITT0054 1 Unvented manifold assembly 3 1 2 Unvented manifold assembly E A B C D Figure 1 Unv...

Страница 9: ...ainer 96 Flexible hose 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve 128 Double check valve with Shut off valve 129 Unvented manif...

Страница 10: ...r 96 Flexible hose 104 Safety relief valve 2 5 bar 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve 128 Double check valve with Shut...

Страница 11: ...1 Strainer 96 Flexible hose 104 Safety relief valve 2 5 bar 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve 128 Double check valve w...

Страница 12: ...100 Safety relief valve 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve 128 Double check valve with Shut off valve 129 Unvented man...

Страница 13: ...pipe from tundish with continuous fall 1 in 200 5 Discharge below fixed grating 6 Trapped gully Sizing of copper discharge pipe 4 for common temperature relief valve outlet sizes Valve outlet size Mi...

Страница 14: ...er supply 2 Open both cold and hot water taps which are situated as low as possible in the building to depressu rise the system E E Please note that there can be some water remaining in the cold water...

Страница 15: ...Appendix UK 15...