Displacement Limiters Adjustment
Adjust Displacement Limiters
W
Warning
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious
injury and/or infection. Relieve pressure in the system before removing hoses, fittings, gauges, or
components.
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
To protect against unintended movement, secure the machine or disable / disconnect the mechanism
while servicing.
C
Caution
Contamination can damage internal components and void the manufacturer’s warranty. Take
precautions to ensure system cleanliness when removing and reinstalling system lines.
1. Install a flow meter in outlet line to measure pump flow.
2. Start the prime mover and allow fluid to reach normal operating temperature.
3. Adjust the control properly to make sure the pump at maximum displacement.
4. Loosen the maximum or minimum displacement limiter lock nut with an external hex wrench and
turn the adjusting screw with an internal hex wrench until the desired flow is achieved.
Option
Description
Maximum displacement
•
Clockwise turn decreases displacement
•
Counter-clockwise turn increases displacement
Minimum displacement
•
Clockwise turn increases displacement
•
Counter-clockwise turn decreases displacement
Displacement change per turn
Displacement
65
130/145
193
260
Max. displacement
change per turn
4.7cm
3
/rev
11 cm
3
/rev
15 cm
3
/rev
19 cm
3
/rev
Min. displacement
change per turn
6cm
3
/rev
9 cm
3
/rev
14 cm
3
/rev
18 cm
3
/rev
5. While holding the position of the adjusting screw, torque the lock nut to required torque.
Wrench sizes and Torque
65
130/145
193
260
Screws
5 mm
5 mm
8 mm
8 mm
Nuts
17 mm
17 mm
24 mm
24 mm
43~48 N·m
[380.58~424.84 lbf·in]
43~48 N·m
[380.58~424.84 lbf·in]
180~206 N·m
[1593.13~1823.25 lbf·in]
180~206 N·m
[1593.13~1823.25 lbf·in]
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Adjustments
42 |
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201