![Danfoss ADAP-KOOL AKD 102 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/danfoss/adap-kool-akd-102/adap-kool-akd-102_operating-instructions-manual_3421853086.webp)
7.2.5 4-** Limits / Warnings
Par
. N
o
. #
P
a
rame
ter
des
cri
pti
o
n
D
e
faul
t val
u
e
4
-set-up
C
hange
dur
ing
op
er
ation
Conve
r-
si
o
n
in
d
e
x
Typ
e
4-1*
Mo
to
r Limits
4-10
Mo
to
r Speed
Direction
[0]
C
lock
w
is
e
A
ll
se
t-
u
p
s
F
A
L
S
E
-
U
in
t8
4-11
M
o
to
r Sp
eed
Lo
w
Li
m
it
[
R
P
M
]
E
xp
re
ssi
onLi
mit
All
se
t-
u
p
s
TRUE
67
Ui
nt16
4-12
Mo
to
r S
p
e
e
d
L
o
w
L
imi
t [Hz]
E
xp
re
ssi
onLi
mit
A
ll
se
t-u
p
s
T
RU
E
-1
U
int16
4-13
Mo
to
r Spe
e
d
Hi
gh
Lim
it
[RPM]
E
xp
re
ssi
onLi
mit
All
se
t-
u
p
s
TRUE
67
Ui
nt16
4-14
Mo
to
r Spe
e
d
Hi
gh
Lim
it
[Hz]
E
xp
re
ssi
onLi
mit
A
ll
se
t-u
p
s
T
RUE
-1
U
int16
4-16
T
o
rque
Limit
Motor
Mode
110.0
%
All
se
t-
u
p
s
TRUE
-1
Ui
nt16
4-17
T
o
rque
Limit
Ge
ne
ra
tor
Mode
100.0
%
A
ll
set
-ups
T
RUE
-1
U
int16
4-18
Cu
rre
n
t L
im
it
E
xp
re
ssi
onLi
mit
All
se
t-
u
p
s
TRUE
-1
Ui
nt32
4-19
Ma
x
Output
F
re
q
uen
cy
E
xp
ressi
onLi
mit
A
ll
se
t-u
p
s
F
A
L
SE
-1
Uint16
4-5*
Ad
j.
W
a
rn
ings
4-50
War
n
in
g
C
u
rren
t L
o
w
0.00
A
A
ll
set
-ups
T
RUE
-2
U
int32
4-51
War
n
in
g
Cu
rre
n
t Hi
gh
ImaxVLT
(
P
1637)
All
se
t-
u
p
s
TRUE
-2
Ui
nt32
4-52
War
n
in
g
S
p
ee
d
Low
0
RPM
A
ll
set
-up
s
T
RUE
6
7
U
int16
4-53
Warn
in
g
S
p
ee
d
High
output
Spe
e
d
Hig
h
Limit
(P
413)
All
se
t-
u
p
s
TRUE
67
Ui
nt16
4-54
War
n
in
g
Re
feren
ce
Lo
w
-999999
.000
N
/A
A
ll
set
-ups
T
RUE
-3
Int32
4-55
Warn
in
g
Re
feren
ce
High
9
99999.
000
N
/A
All
se
t-
u
p
s
TRUE
-3
In
t3
2
4-56
War
n
in
g
F
eed
back
Lo
w
-999
999.000
Re
fere
n
ceFe
e
d
b
ackUn
it
A
ll
set
-ups
T
RUE
-3
Int32
4-57
Wa
rn
in
g
F
eed
ba
ck
H
igh
999999.
000
Re
feren
ceFe
e
d
b
ackUn
it
All
se
t-
u
p
s
TRUE
-3
In
t3
2
4-58
Missing
Mo
to
r
P
h
as
e
Functi
on
[1]
On
All
se
t-u
p
s
T
RUE
-
Uint8
4-6*
Spe
e
d
B
y
pass
4-60
B
y
pas
s
Sp
ee
d
F
rom
[RPM]
E
xp
re
ssi
onLi
mit
A
ll
se
t-u
p
s
T
RU
E
6
7
U
int16
4-61
By
p
a
ss
S
p
e
e
d
F
ro
m
[
H
z]
E
xp
re
ssi
onLi
mit
All
se
t-
u
p
s
TRUE
-1
Ui
nt16
4-62
B
y
pas
s
Sp
ee
d
To
[RPM]
E
xp
re
ssi
onLi
mit
A
ll
se
t-u
p
s
T
RU
E
6
7
U
int16
4-63
By
p
a
ss
S
p
e
e
d
T
o
[
H
z]
E
xp
re
ssi
onLi
mit
All
se
t-
u
p
s
TRUE
-1
Ui
nt16
4-64
Sem
i-Au
to
Byp
a
ss
Se
t-u
p
[0
] Off
A
ll
s
e
t-
up
s
F
ALSE
-
U
in
t8
How to Programme the Frequ...
ADAP-KOOL
®
Drive Operating Instructions
86
MG.11.L4.02 - ADAP-KOOL
®
Drive
7
7