Auxiliary pad
If a second pump is used, you must remove it. You don’t need to remove auxiliary pads to remove the
end cap.
1. Remove the plate cover screws (J130) and remove the cover plate (J110).
2. Remove the coupling (J140) and the pad seal (J120). If you have an auxiliary B pad, discard the O-ring
(J120). The pad seal for an auxiliary A pad is reusable if undamaged.
3. Remove the auxiliary pad screws (J100) with an 8 mm internal hex wrench and remove the adapter
(J085).
4. Remove and discard the O-rings (J090, J095).
5. Remove the coupling (J140).
J140
J095
J100
J090
J085
J120
J110
J130
J140
J095
J100
J090
J085
J120
J110
J130
P109053
Item
Wrench size
J130
9/16 inch
J110
8 mm internal hex
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Disassembly
©
Danfoss | April 2017
AX00000305en-US0101 | 7
Содержание 45 K2 Series
Страница 1: ...Repair Instructions Axial Piston Open Circuit Pumps Series 45 K2 powersolutions danfoss com...
Страница 37: ...Repair Instructions Series 45 Frame K2 Axial Piston Pumps Danfoss April 2017 AX00000305en US0101 37...
Страница 38: ...Repair Instructions Series 45 Frame K2 Axial Piston Pumps 38 Danfoss April 2017 AX00000305en US0101...
Страница 39: ...Repair Instructions Series 45 Frame K2 Axial Piston Pumps Danfoss April 2017 AX00000305en US0101 39...