Fan Drive Control
Inspection
1. Inspect the pressure limiter for wear. Check for contamination and damage to the O-rings, replace if
necessary.
2. Inspect the control housing for damage. Check the spool bores for excessive wear. Remove debris
from orifices if necessary.
3. Carefully inspect the spool. Ensure the sealing lands are free of nicks , burrs and scratches. Check the
ends that contact the spring guides for wear. Replace the spool if necessary.
4. Check the spool for free (smooth) movement in housing bore.
5. Check the orifices (H030 and G020) for contamination, and for cavitation damage.
6. Check the solenoid cartridge for damage, bending, free pin movement.
7. Check the coil for damage Check the plastic plug for contamination.
8. Check the coil connector for contamination or overheat marks, deformation, connector pins are not
damaged or bent, or missing. Replace the coil if necessary.
9. Check the control o-rings for damage, or cracks and replace if necessary.
10. Clean and lubricate all spools, bores, and seals with a light coating of hydraulic oil.
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Inspection
22 |
©
Danfoss | April 2017
AX00000305en-US0101
Содержание 45 K2 Series
Страница 1: ...Repair Instructions Axial Piston Open Circuit Pumps Series 45 K2 powersolutions danfoss com...
Страница 37: ...Repair Instructions Series 45 Frame K2 Axial Piston Pumps Danfoss April 2017 AX00000305en US0101 37...
Страница 38: ...Repair Instructions Series 45 Frame K2 Axial Piston Pumps 38 Danfoss April 2017 AX00000305en US0101...
Страница 39: ...Repair Instructions Series 45 Frame K2 Axial Piston Pumps Danfoss April 2017 AX00000305en US0101 39...