Required tools
The service procedures described in this manual can be performed using common mechanic’s hand
tools. Special tools, if required are shown. Calibrate pressure gauges frequently to ensure accuracy. Use
snubbers to protect gauges.
Port locations and gauge installation
Gauge port locations are shown below. General pressure gauges and fittings are detailed in the table.
Gauge and port information
Port
Purpose
Range of gauge
Fitting
M2
*
System pressure
0-300 bar [0-5000 psi]
7/16 - 20 O-ring fitting
L1, L2
Case drain port
0-10 bar [0-100 psi]
7/8 - 14 O-ring fitting
X
LS signal
0-300 bar [0-5000 psi]
7/16 - 20 O-ring fitting (tee
into LS signal line)
*
The M2 port is not available as a standard option.
Gauge port locations, axial ported units
L2
S
B
L1
X
P109050
M2
Pressure gauges and fittings, axial
Port
Description
Mounting
Diameter
B
Outlet
SAE J1926
1.3125-12
L1
Case drain
SAE J1926
0.875-14
L2
Case drain
SAE J1926
0.875-14
S
Inlet
SAE J1926
1.875-12
X
LS signal
SAE J1926
0.4375-20
Service Manual
Series 45 Frame K2 Open Circuit Axial Piston Pumps
Pressure measurement
16 |
©
Danfoss | April 2017
AX00000301en-US0101
Содержание 45 Frame K2 Series
Страница 1: ...Service Manual Open Circuit Axial Piston Pumps Series 45 Frame K2 powersolutions danfoss com...
Страница 38: ...Service Manual Series 45 Frame K2 Open Circuit Axial Piston Pumps 38 Danfoss April 2017 AX00000301en US0101...
Страница 39: ...Service Manual Series 45 Frame K2 Open Circuit Axial Piston Pumps Danfoss April 2017 AX00000301en US0101 39...