Installation manual for DM700 ECDIS
Copyright Danelec Marine A/S
MAN11805-10
Page 54/67
10 Detailed specification of the IEC 61162-450 interface
IEC 61162-450 data is only supported on the external network interfaces (LAN2)
10.1 Maximum data rate
The maximum output rate for IEC 61162-450 image data is 2MB/s.
10.2 Maximum datagram size
Re-transmittable binary image transfer: 1400 Bytes
10.3 Default parameters
Transmission groups:
Re-transmittable binary image transmission group 1 (239.192.0.26:60026)
Default SFI = EI0001
10.4 Supported transmission groups
Re-transmittable binary image transfer transmission group 1-5
(239.192.0.26:60026) - (239.192.0.30:60030)
10.5 Description of other network function, ONF
10.5.1
NavBox interface (chart data)
TCP/IP port 445 (SMB)
10.5.2
TCP IEC61162-1 data
TCP client or TCP Server
Port range: 1024 < x < 50000
10.5.3
IP addresses used internally by the ECDIS
192.168.203.x/255.255.255.0
192.168.156.x/255.255.255.0
The ECDIS cannot communicate with external equipment using these addresses.
Содержание DM700 ECDIS
Страница 61: ...Installation manual for DM700 ECDIS Copyright Danelec Marine A S MAN11805 10 Page 61 67...
Страница 63: ...Installation manual for DM700 ECDIS Copyright Danelec Marine A S MAN11805 10 Page 63 67...
Страница 65: ...Installation manual for DM700 ECDIS Copyright Danelec Marine A S MAN11805 10 Page 65 67...
Страница 66: ...Installation manual for DM700 ECDIS Copyright Danelec Marine A S MAN11805 10 Page 66 67...
Страница 67: ...Installation manual for DM700 ECDIS Copyright Danelec Marine A S MAN11805 10 Page 67 67...