1.4 Mounting options and angle settings
Mounting holes are provided on the tie bar of the bracket.
▪ Two centered 9 mm (0.35") holes at the d&b standard spacing
of 115 mm (4.5") are provided.
This allows the cabinet to be horizontally flown from overhead
bars or truss with a tube diameter between 40 mm and 70 mm
(1.5" and2.75") using the Z5010 TV spigot with fixing plate in
conjunction with the Z5012 Pipe clamp.
▪ Five mounting holes are provided at each end of the tie bar to
attach the Z5044 MAX Bracket connector, the Z5053 Ci60/
Ci90 Bracket connector or the Z5054 Ci60/Ci90 Flying
adapter.
One 11 mm (0.43“) hole
[a] and two semi-circular slots [b], [c]
are located at each end of the bracket.
Using the M10 threaded inserts at the top and bottom of the
loudspeaker cabinet, the bracket can be attached in different ways
to allow angle settings over a range of 105°, starting from +15°
through to –90°. The following mounting options and angle
settings are possible.
Option 1
The bracket is attached to the cabinet with hole
[a] facing to the
back of the cabinet. One bolt is fitted into slot
[b] and the second
bolt is fitted into slot
[c].
The vertical coverage angle can be set over a range of 25°
starting from 0° to –25°.
Option 2
The bracket is attached to the cabinet with hole
[a] facing to the
back of the cabinet. One bolt is fitted into hole
[a] and the second
bolt is fitted into slot
[c] to allow the bolt to move in slot [c].
The vertical coverage angle can be set over a range of 60°
starting from –30° to –90°.
Option 3
The bracket is attached to the cabinet with hole
[a] facing to the
back of the cabinet. Both bolts are fitted into slot
[b].
The vertical coverage angle can be set over a range of 15°
starting from 0° to +15°.
Z5554 Mounting holes
d&b Z5554 Mounting instructions 1.1 en
5